Danfoss ERC 112D Скачать руководство пользователя страница 1

DKRCE.PI.RL0.A2.02

520H10340

DKRCE.PI.RL0.A2.02 / 520H10340

© Danfoss | DCS (az) | 2015.09

Installation guide | ERC 112

36.5 mm

28 mm

78.25 mm

82.25 mm

78.25 mm

71 mm

28.5 mm

71 mm

30 mm

1

S1 S2 S3 S4 di

DO1

Outputs

Inputs

ERC 112D

100 – 240 V AC ± 10% 50/60 Hz 0T55

L

N

DO2 DO3 DO4

2

3

4

5

6

1

S1 S2 S3 S4 di

DO1

Outputs

Inputs

ERC 112C

100 – 240 V AC ± 10% 50/60 Hz 0T55

L

N

DO2 DO3

2

3

4

5

2

3

1

4

SC

SC

^

^

^

^

ECO

Installation Guide

ERC 112

Bottle Cooler Controller

Power Supply 

100 – 240 V AC Switch mode power supply. Average 0.7 W

Input

5 inputs: 4 analogue (digital), 1 digital; user specific assignment 
• Air / Evaporator / Condenser 

• Door sensor: all types, user specific 

• Light sensor: Danfoss ECO light 
  sensor 

• Motion sensor 

Output

UL60730

EN60730

"DO1" 
(Compressor relay)

120 V AC: 16 A resistive /
FLA 16/LRA 72

240 V AC: 10 A resistive /
FLA 10 / LRA 60

16(16) A

"DO4"

8 A resistive, FLA 2 / LRA 
12, TV-1

8 A resistive, 2(2) A 

"DO5"

FLA 2 / LRA 12, TV-1

8 A resistive, 2(2) A

"DO6"

FLA 2 / LRA 12, TV-1

8 A resistive, 2(2) A
Max 10 A total "DO4-6"

Probes 

• Danfoss NTC sensors and Danfoss ECO accessories
• Danfoss PT1000 ohm / 0°C 

Connectors 

• Modular connector system for OEM customers, with optional output screw 
  terminal adapter 
• Input connector type: Rast2 5 Edge connectors 
• output connector type: RAST 5 standard 

Programming 

Programming with Danfoss ERC docking station, integrated system 

Assembly 

3 types for all controls: 
front mounting; brackets; fully integrated solution 
(requires OEM specific design of mounting hole) 

Display 

LED display, 3 digit, decimal point and multi functionality icons; °C / °F scale 

Keypad 

4 buttons (integrated IP65 design), 2 left, 2 right; user programmable 

Operating 

Conditions 

0 °C – 55 °C, 93% rH 

Storage 

Conditions 

-40 °C – 85 °C, 93% rH 

Range of 

Measurement 

-40 °C – 85 °C 

Protection 

Front: IP65
Rear: water and dust protection corresponds to IP31, 
accessibility of connectors limit rear part rating to IP00 

Environmental 

Pollution degree II, non-condensing 

Resistance to 

heat & fire 

Category D (UL94-V0) 

EMC category 

Category I 

Operating Cycles 

Compressor relay: more than 175.000 at full load (16 A (16 A)) 

Approvals

• R290 / R600a end-use applications 
  employing in accordance to 
  EN / IEC 60335-2-24, annex CC and 
  EN / IEC 60335-2-89, annex BB 
• Glow wire according to 
  EN / IEC 60335-1 / IEC / EN 60730 
• UL60730 
• NSF 
• CQC 
• GOST R 60730 

• These approvals are only valid when 
   using the accessories approved 

Technical specification

Menu structure

Operation Changing the setpoint:

Two kinds of left buttons - see pictures 1. and 3.

Example of changing a parameter

Turning ON/OFF the ECO function

Password protection

Acknowledging alarm

Activating manual defrost

Dimensions

Wiring diagram

Configuration of outputs

Configuration of inputs

Configuration of inputs

ERC front and button functionality

Functional description of used sensors

Front mounting

(Lock with frame)

Rear mounting

(Lock with clips) 

Relay 

outputs

Compress.

Defrost

Fan

Light

Alarm

Heating 

application

DO1 (o1C)
DO2 (o2C)
DO3 (o3C)
DO4 (o4C)

Input/

sensor

Cabinet 

sensor

Evapor.

sensor

Conden. 

sensor

Door 

sensor

Light 

sensor

Movem.

sensor

Comm.

S1
S2
S3
S4

di

Control temperature sensor

The control sensor must always be connected and is used for controlling the cut-in and cut-out of 

the compressor according to the set-point. The sensor is also used for the displayed temperature. 

Most common placement is in the return air to the evaporator.

Evaporator sensor

The evaporator sensor is only used for de-icing of the evaporator and has no control purpose. 

Place the sensor where the ice melts last.

Please be aware of that sharp fins can damage the cable.

Condenser temperature sensor

The condenser sensor is used to protect the compressor against high pressure when the 

condenser is blocked or the condenser fan fails. 

Place the sensor at the liquid side of the condenser. Use a metal bracket or metal tape to ensure 

good thermal conductivity. Be sure that the cable does not pass hot spots at the compressor or 

condenser that exceeds 80 °C.

Configurable functionality

Button

Basic 

function

Not 

operating ON/OFF

Increase 

setpoint

Decrease 

setpoint

Toggle 

defrost

Toggle 

light

1 press

OK

1 pess and hold
2 press

BACK

2 pess and hold
3 press

UP

3 pess and hold
4 press

DOWN

4 pess and hold

Configurable functionality

Button

Toggle 

ECO

Toggle 

pulldown

Increase 

display 

intensity

Decrease 

display 

intensity

Toggle °C 

or F

Info menu

1 press
1 pess and hold
2 press
2 pess and hold
3 press
3 pess and hold
4 press
4 pess and hold

Press and 

hold 5 sec to 

access the 

menu

1. Parameter group

1. Parameter name

Lower left button

Lower left button

Scroll through parameters

Scroll through menu group

The display shows the current temperature

Current temperature

1.

1.

2.

2.

3.

3.

Flashing temperature setpoint

Press: UP/DOWN to adjust setup

After 30 seconds, the display automatically 

reverts to showing the current temperature

Defrost symbol is shown in defrost mode

Defrost symbol will disappear after the defrost is 

finished.

(The dEF text during the defrost is displayed or 

not based on the cabinet manufacturer settings)

Press briefly 

to start or 

stop defrost

1.

2.

3.

4.

5.

6.

7.

8.

9.

Press and hold 5 sec to access 

the menu

Press: UP / DOWN to scroll 

through the menu

Press: UP / DOWN to find the

desired parameter

Press: UP / DOWN to enter the

desired value

To select: press the lower 

left button (OK)

To confirm: press the lower

left button (OK)

To accept: press the lower left 

button (OK) and return to 

parameter name

To exit without accept: 

press the upper left button (BACK) 

To return to parameter group: 

press upper left button (BACK)

To return to menu: 

press upper left button (BACK)

After 30 seconds of inactivity, 

the display automatically 

reverts to showing the current 

temperature 

Scroll through parameters group

Scroll through group "dEF" parameters

1.

2.

The green ECO symbol is list

when in ECO mode

Press briefly to enter 

ECO mode

Password protection on three levels:

LEVEL 1: shop (daily use by shop personnel)

LEVEL 2: ser (service technician)

LEVEL 3: OEM (OEM programming

Press and hold 5 

sec to access the 

menu

1.

2.

The alarm code flashing alternately 

with the temperature and the 

alarm symbol is displayed 

After the acknowledge the 

temperature is displayed and the 

alarm symbol remains  shown 

Press any button to acknowlege

Отзывы: