NOTICE
Danfoss Power Solutions recommends that you save the original system configuration to a
QSC file for each motor when you launch your software with that motor for the first time. This
allows you to return to the configuration of your original shipped state at any time. See “Save
to file” in
Section 8.5
of this manual.
8.2.1
Status Bar
As the Danfoss Power Solutions Motor Diagnostic Software starts, it contacts the controller via the COM port.
The Status Bar (
) at the bottom of the application window communicates all the details of the RS232
communication. It displays status messages, the current bytes-per-second rate, the COM port, the baud rate, and
the current errors-per-second rate.
Figure 8.13: Status Bar
The Status Bar Communication Messages table (below) shows the communication messages that occur in the
Status Bar (
When errors occur, the software provides additional information through message boxes or other dialog boxes.
For example, if the software encounters a device that uses an older version of firmware, the software informs you
and inquires if you wish to update or just run the application. Alternatively, if communication is not possible, the
software either exits or returns to the “Choose COM Port” dialog box.
Table 8.2: Status Bar Communication Messages
Message
Description
Communication down,
continuing to try...
Communication between the PC and the device has not yet been
established or has failed. The PC will continue to try to establish
communication every five seconds until you stop it via the “Choose COM
Port” Action.
Have gotten the COM port
First message during initial contact.
Found device, initializing
interface...
The device has answered; software is asking for identification.
Initializing Device...
Identification received; initializing communication with the device.
Negotiating baud...
Baud rate is being negotiated between the PC and the device. The highest
supportable baud will be selected.
Reading Eerom...
The internal persistent memory is being read. This memory contains
configuration, calibration, and error event data.