
Installation Instructions
Removing the Top Fan
To remove and replace the top fan, use the following procedures. Refer to
1.
Remove 2 screws (T25) from the fan housing.
2.
Slide the fan housing and fans out from under the retaining clips.
3.
Unplug the in-line connector attaching the fan cable.
4.
Feed the cable through the cable access hole.
5.
Lift the fans from the pins in the fan housing.
Installing the Top Fan
1.
Place the fans over the pins in the fan housing. Check that the air direction arrows point upward and away from the drive.
2.
Feed the fan cables through the cable access hole on the top plate.
3.
Reconnect the in-line cable connector.
4.
Slide the fan housing and fans into position under the retaining clips.
5.
Secure 2 screws (T25) in the fan housing.
1
Fan housing
4
Screw (T25)
2
Mounting pin (inside housing)
5
Cable access hole
3
Fan
6
Retaining clip
Illustration 1.1 Top Fan
Installation Instructions
Top Fan Replacement for E3h/E4h Drives
2
Danfoss A/S © 06/2017 All rights reserved.
MI35N102