background image

Testing criteria

Climatic

Condition

Rating

Cold/heat storage and operation

IEC 60068-2-1, IEC 60068-2-2

Fogging

IEC 60068

Temperature change

IEC 60068-2-14

UV tests

ASTM G155

Sunlight radiation

ISO 16750-4

Temp humidity voltage

IEC 60068-2-38

Chemical

Condition

Rating

Chemical resistance

ISO 16750-5

Mechanical

Condition

Rating

Vibration, resonance

IEC 60068-2-6

Vibration, operation

IEC 60068-2-64

Bump

IEC 60068-2-29

Shock

IEC 60068-2-27

Free fall

IEC 60068-2-32

Technical Information

DP7XX Series Displays

Product ratings

 

©

 Danfoss | November 2016

L1315553 | BC00000223en-US0504 | 19

Содержание dp700

Страница 1: ...Technical Information PLUS 1 Mobile Machine Displays DP7XX Series powersolutions danfoss com ...

Страница 2: ...on drawing with new bracket displayed 0501 October 2015 Added the DP730 series information EA November 2014 Added DP720 LCD statement Corrected Pin Assignments callouts on image of back of Display DC March 2014 Changed note to warning DB December 2013 LCD option table added changed Panel Mounting Kit part number DA October 2013 Various CA July 2013 Added section BA May 2013 First edition AA Techni...

Страница 3: ... 11 Multifunction 12 Encoder 13 Outputs 13 Digital output 13 USB 13 Video 14 Real Time Clock RTC 14 Controller Area Network CAN specifications CAN shield analog inputs 15 Analog input 15 CAN communication 15 Gateway channels 15 Memory NV memory 17 FRAM Memory 17 Vault Memory 17 Product ratings Electrical 18 Environmental 18 Testing criteria 19 Maintenance guidelines LCD module 20 LCD press and hol...

Страница 4: ...DP730 connectors pin assignments 25 Machine wiring guidelines 26 Machine welding guidelines 26 Technical Information DP7XX Series Displays Contents 4 Danfoss November 2016 L1315553 BC00000223en US0504 ...

Страница 5: ...API is specifications for programming variable settings API specifications are the definitive source of information regarding pin characteristics PLUS 1 GUIDE User Manual This user operation manual OM details information regarding the PLUS 1 GUIDE tool set that is used to build PLUS 1 applications This OM covers the following broad topics How to use the GUIDE graphical application development tool...

Страница 6: ...esponsibility for Danfoss products being incorrectly applied or the system being programmed in a manner that jeopardizes safety All safety critical systems shall include an emergency stop to switch off the main supply voltage for the outputs of the electronic control system All safety critical components shall be installed in such a way that the main supply voltage can be switched off at any time ...

Страница 7: ...t products A screen editor allows easy development of applications by programmers without formal software development training The expertise from a software engineer is not needed to find your way around in PLUS 1 GUIDE Linux operating system DP7XX Series Displays contain embedded Linux operating system software that is copyrighted software licensed under the GPL Version 2 0 or LGPL Version 2 1 Li...

Страница 8: ...2 02 04 01 11126327 DP730 01 02 02 02 02 01 00 11162882 DP730 02 02 02 02 02 01 00 11162884 DP730 03 02 02 02 02 01 00 11162885 DP730 01 02 02 02 02 01 01 11162886 DP730 02 02 02 02 02 01 01 11162887 DP730 03 02 02 02 02 01 01 11162888 A Model name Code Description DP700 PLUS 1 Mobile Machine Displays DP710 DP720 DP730 B LCD options Code Description 01 Value Transmissive 02 Standard Transmissive 0...

Страница 9: ...SB device rear USB host rear G Application log vault memory Code Description 01 16 MB H Bezel color Code Description 00 Black 01 Gray Related products Connector bag assemblies Description Part numbers 12 pin connector kit 16 to 20 AWG 10102025 12 pin connector kit 20 to 24 AWG 10100944 Mating connector kit with camera cable 11130520 USB cable device only 11130518 USB cable device and host 11130519...

Страница 10: ... Professional Software includes 1 year of software updates a single user license Service and Diagnostic Tool and Screen Editor 11179523 annual renewal with 11179524 to keep the software updates Technical Information DP7XX Series Displays Ordering information 10 Danfoss November 2016 L1315553 BC00000223en US0504 ...

Страница 11: ... 1 0 3 To 5 V Input impedance with pull up down kΩ 7 27 0 2 To 2 5 V Normal range multifunction input Description Unit Minimum Maximum Comment Range V 0 5 75 Resolution mV 1 4 Worst case error mV 20 U 2 Input impedance kΩ 233 3 To 0 V Input impedance with pull down kΩ 14 1 0 3 To 0 V Input impedance with pull up kΩ 14 1 0 3 To 5 V Input impedance with pull up down kΩ 7 27 0 2 To 2 5 V High range m...

Страница 12: ...nd quad Hz 0 5000 When measuring phase or quadrature counts Low threshold voltage V 1 1 2 6 High threshold voltage V 2 2 4 4 Input impedance kΩ 233 3 To 0 V Input impedance with pull down kΩ 14 1 0 3 To 0 V Input impedance with pull up kΩ 14 1 0 3 To 5 V Input impedance with pull up down kΩ 7 27 0 2 To 2 5 V Resistance input Description Unit Minimum Maximum Comment Range Ω 0 10000 In steps of 1 Ω ...

Страница 13: ...d decremented by two for every detent The counter is incremented when the A signal is the leading phase and decremented in the opposite case Outputs Digital output Only to be used for buzzer output USB USB Input Output Description Unit Minimum Maximum Typical Comment 2 0 full speed Mbit s 12 Vbus input voltage V 4 4 Vbus input resistance kΩ 70 Vbus 5 25 V Short circuit protection No damage V 0 36 ...

Страница 14: ...t power supply it should meet the specification of the camera in regards of the voltage type and range the current and voltage amount it can supply to its load stability of the output voltage and current under varying line and load conditions operating storage temperature ranges The use of a different power supply for the camera can create noise on the signal line which will affect its functionali...

Страница 15: ...Ω 233 3 Analog input Analog input 5 V only Description Unit Minimum Maximum Comment Allowed voltage at pin V 0 36 Measuring range V 0 5 75 Resolution mV 1 4 Worst case error mV 20 U 2 Input impedance kΩ 233 3 CAN communication CAN communication Description Unit Minimum Maximum Typical Comment Available baud rates kBd 50 1000 50 With 120 Ω termination The default baud rate is 250kbit 100 125 250 50...

Страница 16: ...LUS 1 Service Tool communication Another PLUS 1 Service Tool can be connected to the CAN bus by using the following gateway channels Simultaneous usage gateway channels Channel Description 0 CAN 0 and CAN 1 1 or 4 CAN 1 2 or 5 CAN 0 3 or 6 No CAN port Technical Information DP7XX Series Displays Controller Area Network CAN specifications 16 Danfoss November 2016 L1315553 BC00000223en US0504 ...

Страница 17: ... of over 100 trillion cycles which is ideal for datalogging 2kB is available for application Vault Memory DP7XX Series Displays have 16 MB of flash vault memory application logging memory Application developers use this memory to log machine event data then use the PLUS 1 Service Tool to extract the logged data Accessing non volatile or application log memory can delay the service tool scan Techni...

Страница 18: ...st product damage and possible injury do not exceed power supply voltage ratings and do not store this product where flammable gasses or chemicals are present Environmental Temperature Description Units Minimum Maximum Comment Operating temperature C F 30 22 60 140 Storage temperature C F 30 22 80 176 Ingress Protection IP rating Series Rating Comment DP700 DP710 DP720 IP67 With mating connector i...

Страница 19: ...ation ISO 16750 4 Temp humidity voltage IEC 60068 2 38 Chemical Condition Rating Chemical resistance ISO 16750 5 Mechanical Condition Rating Vibration resonance IEC 60068 2 6 Vibration operation IEC 60068 2 64 Bump IEC 60068 2 29 Shock IEC 60068 2 27 Free fall IEC 60068 2 32 Technical Information DP7XX Series Displays Product ratings Danfoss November 2016 L1315553 BC00000223en US0504 19 ...

Страница 20: ...return the display to Danfoss to be serviced Clean the display s housing and protective glass with a clean soft damp cloth or mild dishwashing detergent because abrasive pads or solvents including alcohol benzene and paint thinner can cause scratching and discoloration LCD press and hold feature The DP7XX LCD press and hold registers for 5 to 6 seconds then releases The software inside the touch s...

Страница 21: ... 2 95 0 02 80 08 0 50 3 15 0 02 75 00 0 50 2 95 0 02 27 60 0 50 1 09 0 02 4X M4 P200189 235 20 9 26 163 50 6 44 9 90 0 39 42 60 1 68 177 80 7 00 REF Technical Information DP7XX Series Displays Installation Danfoss November 2016 L1315553 BC00000223en US0504 21 ...

Страница 22: ... 20 161 90 6 37 12 00 0 47 40 50 1 59 75 00 0 50 2 95 0 02 80 08 0 50 3 15 0 02 75 00 0 50 2 95 0 02 27 60 0 50 1 09 0 02 4X M4 P200188 Technical Information DP7XX Series Displays Installation 22 Danfoss November 2016 L1315553 BC00000223en US0504 ...

Страница 23: ...ds Association Mount Standards The VESA hole pattern for these displays is 75 00 mm x 75 00 mm 02 95 in x 02 95 in There are four holes for four M4 screws 0 7 mm 0 3 in thread x 12 mm 0 47 in maximum depth millimeters inches 75 00 0 50 2 95 0 02 80 08 0 50 3 15 0 02 75 00 0 50 2 95 0 02 27 60 0 50 1 09 0 02 4X M4 P200158 Disconnect your machine s battery power before connecting power and signal ca...

Страница 24: ... Video power supply C1 P2 Power supply C6 P3 USB host D C5 P3 USB device D C3 P3 C4 P3 Video signal input 2 C1 P3 CAN0 High C6 P4 USB host GND C5 P4 USB device GND C3 P4 Video signal input ground C4 P4 Video signal input ground C1 P4 CAN0 Low C5 P5 USB host GND RS232 GND C3 P5 NC C4 P5 NC C1 P5 AIN CAN Shield C5 P6 USB host D RS232 RxD C1 P6 CAN1 High AIN DIN C5 P7 USB host D RS232 TxD C1 P7 CAN1 ...

Страница 25: ...wer supply C5 P3 USB device D C4 P3 Video signal input 2 C3 P3 Video signal input 1 C1 P3 CAN0 High C5 P4 USB device GND C4 P4 Video signal input ground C3 P4 Video signal input ground C1 P4 CAN0 Low C5 P5 USB host GND RS232 GND C4 P5 NC C3 P5 NC C1 P5 CAN shield AIN C5 P6 USB host D RS232 RxD C1 P6 CAN1 High AIN DIN C5 P7 USB host D RS232 TxD C1 P7 CAN1 Low AIN DIN C5 P8 USB host Vbus C1 P8 Senso...

Страница 26: ...chors that will allow wires to float with respect to the machine rather than rigid anchors C Caution Unused pins on mating connectors may cause intermittent product performance or premature failure Plug all pins on mating connectors W Warning Unintended movement of the machine or mechanism may cause injury to the technician or bystanders Improperly protected power input lines against over current ...

Страница 27: ...Technical Information DP7XX Series Displays Danfoss November 2016 L1315553 BC00000223en US0504 29 ...

Страница 28: ...K 6430 Nordborg Denmark Phone 45 7488 2222 Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New District Shanghai China 201206 Phone 86 21 3418 5200 Danfoss can accept no responsibility for possible errors in catalogues brochures and other printed material D...

Отзывы: