DEVIreg™ 850 ground and roof sensors
Installation and user manual
4
1 .2
Control zones
A DEVIreg™ 850 and up to 4 sensors are able to control an area as a single zone, but can
also control more areas as 2 separated control zones.
2 control zones consits of minimum 2 heating el 2-4 sensors and can be:
Combi zones
= when you have both a roof and a ground area
Dual zones
= e.g. if steps should have a better performance than a walkway
If the power supply is limited, both combi and dual zones gives you the possibility to
prioritize which zone to operate first.
A DEVIreg™ 850 and up to 4 sensors give the following 5 control options:
Zone type
Single zone ground
1-4 in one zone
Maximum
4 sensors
in all
Single zone roof
1-4 in one zone
Combi zones
1-3 in one ground
zone
1-3 in one roof zone
Dual zones ground
2-4 split in two zones
Dual zones roof
2-4 split in two zones