20
TPOne-S
Start-up
Method
This feature allows the thermostat to start up the
heating system in three different ways.
Normal -
Heating is turned up or down at the
programmed times.
Delayed start
(or Economy Setting) -
Set the period start times in the normal way
taking into account the time that the building
takes to heat on an average day. The thermostat
monitors switch on time, actual temperature and
wanted temperature and delays the start of the
heating if the actual temperature is close to the
programmed temperature. Delayed Start in TPOne
is dynamic and will adjust automatically to the
home heating characteristics while maximising
energy savings.
Optimised Start
(or Comfort Setting) -
This allows you to programme the time at
which you would like to be up to the required
temperature. The thermostat then calculates
how soon before the required time the heating is
turned up. Optimised Start in TPOne is dynamic
and will adjust automatically to the home heating
characteristics to reach required temperature at
the required time.
Default:
Normal
Temperature
Limits
This allows the upper and lower temperature of
the thermostat setting range to be limited.
Defaults:
Minimum 5°C,
Maximum 35°C
Frost Protect
To help protect against damage to the heating
system caused by extreme low temperatures the
TPOne includes a Frost Protect level. This is the
minimum temperature level and is also used when
the TPOne is placed in standby mode.
Default:
5°C
Temperature
Override
This establishes the degree of manual temperature
override available to the user, No Limit, L/-
2°C or No Override
Default:
No Limit
Installer Settings
(Continued)