background image

5

SMS Commands

Default settings

After the first installation, default settings are as follows:

Password: 0000

Output: OFF (COM-NC closed, Status LED is red)

Default settings can be changed via SMS.

The default settings can be restored at any moment by proceed-

ing as follows:

Turn off the Danfoss Link™ MPB

Press and hold down the manual switch

Power up the Danfoss Link™ MPB (Status LED remains unlit

for approx. 5 sec.)

When the Status LED lights up, release the manual switch

The settings, including the password, have been restored to the

default settings.

Settings are saved in the internal memory of Danfoss Link™ MPB.

In case of power failure, the memorized settings are restored when

switching on.

Commands

N

SMS commands should be sent to the

cell phone number corresponding to

the SIM card inserted in the Danfoss

Link™ MPB.

The format of the SMS command is: PASSWORD # COMMAND

Com-

mand

Function

Example

(Password

0000)

1

Switch ON the output relay (COM-NO

closed, COM-NC open), green LED.

0000#1

 

Danfoss ON (HOME).

 

0

Switch OFF the output relay (COM-NO

open, COM-NC closed), red LED.

0000#0

 

Danfoss OFF (AWAY).

 

Com-

mand

Function

Example

(Password

0000)

?

The Danfoss Link™ MPB replies a Status

Notification SMS, containing the out-

put status and information regarding

the functions activated

0000#?

Pxxxx

Set the password, 4 digits (Ex. from

0000 to 1234). The Danfoss Link™ MPB

sends an SMS showing the new pass-

word.

0000#P1234

N

After executing a command, the Dan-

foss Link™ MPB always replies with a no-

tification SMS.

Error notification SMS

The Danfoss Link™ MPB replies an error notification SMS if the

command sent does not exist or cannot be activated, or if the

command parameter is not valid. Content of this notification SMS

is: 

ERROR!

If the command SMS starts with a wrong password, (4 digits fol-

lowed by #) the notification SMS is: 

Invalid password!

N

The Danfoss Link™ MPB does not send

any type of notification SMS if the SMS

received is not recognized as valid (ex.

do not start with 4 digits).

Status notification SMS

The Danfoss Link™ MPB replies a status notification SMS after exe-

cuting any of the commands.

Status

Notification SMS

Output ON - NC output open

Danfoss ON (HOME)

Output OFF - NC output closed

Danfoss OFF (AWAY)

Tab. 3: Notification SMS

Smartphone app

For Android phones and iPhones you can download the Danfoss

ButlerApp for easy communication with the Danfoss Link™ MPB.

6

Technical Specifications

Type

Specifications

Operating voltage

12 V DC

Operation voltage (net adapter)

90 - 264 V AC

Standby consumption

Max. 0.5 W

Contact load capacity (max)

0.5 A - 250 V AC
1 A - 30 V DC