All device settings can be reset to their default values by using the Reset device button or by connecting
the C1p06 input to supply voltage for at least 10 seconds. Leave this pin open If resetting the device by
C1p06 is not intended.
Pressing the Device Restart button reboots the application and can be used as an alternative for a power
cycle.
Station mode
1. Go to the WiFi Configuration page and set “Station mode” as Operation mode.
2. If Autoenable is selected, the selected mode will be enabled once the device is powered.
3. Enter the SSID and Password of the network to be connected to.
4. If Autoconnect is selected, once the device is powered it will automatically try to connect to the
configured network.
5. Select the appropriate Country code.
6. If DHCP mode is set to "DHCP diabled" adjust the following settings:
•
IP address and Network mask for the identification of the CS10 device,
•
Gateway address and Gateway metric for identifying the AP to connect to,
•
Primary DNS-server IPv4 addr and Secondary DNS-server IPv4 addr must be set to gather the
IP address of an URI.
When DHCP mode is set to “DHCP enabled” no further settings need to be done.
Using the Save button downloads the data to the device. The actual settings are shown in the section
Actual settings.
Using the Reset button applies a default set of standard parameters.
Technical Information
PLUS+1® CS10 Wireless Gateway
Configuration
8 |
©
Danfoss | November 2020
BC356772124151en-000102