background image

1. Important Instructions

1.1. About this Quick Guide

This manual contains detailed product information and instructions for using the Danfoss CLX
GM equipment.

This document relates to the current version at the time of printing. Danfoss reserves the right
to  make  changes  due  to  the  introduction  of  new  functions  and  improvements.  The  names  of
products and companies mentioned in this document may be registered trademarks of their re-
spective owners.

This Quick Guide contains information about:

Safety

Product overview, system requirements

Technical descriptions

Installation, grid management, and inverter connection

Getting started

Technical data

1.2. Symbols

This manual contains important information accompanied by the following symbols:

The  Attention  symbol  draws  attention  to  a  risk  of  damage  to  components  or
danger to persons if the information provided is not observed. This type of infor-
mation must be observed at all times.

Note: 
The  Note  symbol  marks  supplementary  information  for  improving  operating  processes  as
well as user tips.

1.3. Safety Instructions

The reader must be familiar with the rules and regulations for electrical equipment and connec-
tion  to  the  mains  power  network.  Pay  particular  attention  to  general  safety  regulations  for
working with electrical systems.

Observe the safety instructions below to prevent injury to persons and damage to connected
equipment.

Contact with electrically conductive parts after disconnection from the mains supply can be dan-
gerous. Do not connect the equipment to the mains supply before installation.

1. Important Instructions

2

 

 L00410637-01_02 

 

1

Содержание CLX Series

Страница 1: ...Danfoss CLX Series Quick Guide CLX GM MAKING MODERN LIVING POSSIBLE SOLAR INVERTERS...

Страница 2: ...anagement 9 5 Configuration 10 Configuration 10 Configuring the Network 10 Configuration of CLX GM and Inverters with a DHCP Server Router Dynamic IP 10 Configuration of CLX GM and Inverters without a...

Страница 3: ...accompanied by the following symbols The Attention symbol draws attention to a risk of damage to components or danger to persons if the information provided is not observed This type of infor mation...

Страница 4: ...ied personnel only must perform service Equipment must only be operated at the rated supply voltages 12 24 VDC cor rect polarity A suitable power supply unit is included in the scope of delivery Note...

Страница 5: ...ct upon a certain relay state is performed directly in the master inverter itself The CLX GM is con nected to the receiver and the inverter network and requires no additional configuration Illustratio...

Страница 6: ...are recommended Internet Explorer Version 6 or later Firefox Version 2 or later Note The grid management behaviour is configured directly via the web interface of the TLX Pro or TLX Pro master inverte...

Страница 7: ...with circular connector 12 30 VDC 1 W 2 Ethernet port for LAN 3 Not used 4 Input terminals 12 lines 2 x voltage 6 x relay input S01 S02 S03 S04 S05 S06 4 x analog input 20 mA A1 A1 A2 A2 5 6 Not used...

Страница 8: ...3 2 Display 1 2 3 4 150AA014 10 ESC Illustration 3 3 Front View Legend 1 Cancel Back 2 Down 3 Up 4 Confirm 3 Technical Description L00410637 01_02 7 3...

Страница 9: ...addressing Configuration of the CLX GM depending on whether there is a DHCP server router in the net work or not Refer to Chapter 5 Configuration for further information on how to proceed 4 2 Mountin...

Страница 10: ...anagement Connections The ripple control receiver is connected as follows Input Terminal Strip Function Ripple Control Receiver Connector K S 12 30 VDC K1 S1 Relay input 1 S 12 30 VDC K2 S2 Relay inpu...

Страница 11: ...verter it must be handled on the network layer for example by using VLANs Virtual LAN This requires IT specialist skills and network hardware supporting VLAN 5 2 1 Configuration of CLX GM and Inverter...

Страница 12: ...e the IP configuration of the CLX GM Press Enter Configuration Network DHCP and set it to off The CLX GM reboots automatically and obtain a default static IP address and subnet mask which is IP addres...

Страница 13: ...er control are needed enable both check marks and press Next in order to be guided through the configuration screens Illustration 5 1 Control Types To configure the remotely controlled Power Level Adj...

Страница 14: ...4 according to the requirements of the DNO by entering the appropriate reactive power set point of Q for each relay state specified by the DNO The value entered is set on each inverter and represents...

Страница 15: ...X Pro only Set the Remotely controlled reactive power Q radio button Configure the relay states K1 K4 according to the requirements of the DNO by entering the appropriate Power Factor set point for ea...

Страница 16: ...s the connection to the master inverter The timeout in either case is 10 minutes and fallback mode is automatically disengaged upon restoring the connection The fallback values are distributed to each...

Страница 17: ...Illustration 5 5 Grid Management 5 Configuration 16 L00410637 01_02 5...

Страница 18: ...ing contact Enclosure 2 part fanless metal enclosure for rail mounting IP20 Weight 330 g net without accessories and external AC mains adapter Humidity range 80 non condensing Ambient humidity Indoor...

Страница 19: ...errors in catalogues brochures and other printed material Danfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alterations...

Отзывы: