D
US
© Danfoss | Climate Solutions | 2023.06
AQ450435606290en-US0201| 7
1
Type designation
2
Machine number
3
maximum operating current
4
Starting current (rotor blocked)
5
LP: max. admissible operating
pressure
(g)
Low pressure side
HP: max. admissible operating
pressur
e
(g)
High pressure side
Observe the limits of application
diagrams!
50 Hz
60 Hz
6
Voltage, circuit, frequency
7
Nominal rotation speed
8
Displacement
9
Voltage, circuit, frequency
10 Nominal rotation speed
11 Displacement
12 Oil type filled at the factory
13 Terminal box protection type
Electrical accessories can change
the IP protection class!
}
}
2.2 Name plate
(example)
2
|
Product description
1
2
3
4
5
13
12
7
11
6
10
8
9
SE 55
27,3
32,8
: UL-HGX12e/40 S 3 CO
2
LT
10,7/6,2A
111A
64A
: BC12345A001
Bock GmbH, Benzstr. 7
72636 Frickenhausen, Germany
C85E
6,0
7,2
IP66
100/100 bar
BOCK
/
HG
1 2 e
40 S
CO
2
X
¹
)
HG - Hermetic Gas-Cooled (suction gas-cooled)
²
)
X - Ester oil charge
³
)
ML - Deep freezing at low and medium evaporation temperatures
S - For frequency regulation and extended limits of application
Low Temperature
CO
2
version
HP code for motor size
Compressor version
3)
Swept volume
e-series
Number of cylinders
Size
Oil charge ²
)
Series ¹
)
Identification
UL compressor
LT
3
Öl:
BOCK
lub
E85
123 cfh
148 cfh
LP/HP = 1450/1450 psig
Type
No
Oil: BOCK
lub E85
thermally protected system
UL -
2.3 Type key
(example)
Fig. 3