User manual
Installation, Operation and Maintenance APP S 674 pumps
10
180R9270 / IOM APP S 674 - v01 / 03.2013
Pumps which have a weight above 20 kilos (see
Data sheet, appendix 1) must be handled by
using lifting eyes and slings .
Never use only one sling and make sure the
slings do not slip off the pump .
When the pump is mounted together with an
electric motor, the pump unit always weigh more
than 20 kilos and must be handled by using
slings around the pump unit .
See below examples of where to/not to attach
the lifting slings on the pump unit:
Correct lifting with 2 separate slings:
Wrong lifting:
When lifting the pump unit, one sling must be
attached to the electric motor and one sling
around the pump .
Some motors and pumps have specific lifting
eyes .
Do not use connections/nozzles for lifting!
Do not use only one sling!
Make sure that the unit/load is balanced before
lifting . The centre of the mass varies from pump
unit size to pump unit size .
How to mount the pump and the electric motor
correctly, see appendix 2 , Instruction .
Incorrect lifting can result in personal injury
and/or damage to the pump unit, see appendix
2, Instruction.
4.5 Return to supplier
Please see maintenance chapter 7 .
4.6 Storage
Each pump is tested before shipment, and will
therefore contain water . For storage temperature
and frost protection see appendix 2, Instruction .
The pumps are NOT delivered frost protected
from the factory.
Содержание APP S 674 Series
Страница 5: ...5 180R9270 IOM APP S 674 v01 03 2013 EU Declaration of Conform ity...
Страница 52: ...52 180R9270 IOM APP S 674 v01 03 2013 Parts list APP S 674 pumps 2 521B1248 DKCFN PY 073 G1 02 03 2013...
Страница 71: ...User manual Appendices APP S 674 pumps 71 180R9270 IOM APP S 674 v01 03 2013...