7.2 Assembling
1. Lubricate pistons with clean filtered water.
Insert the pistons arbitrarily.
2. Remove the stop for retainer plate.
4. Place the retainer plate in an angle
corresponding to the orientation of the
swash plate.
5. Tilt the flange and replace the flange
O-ring.
6. Turn the flange and gently push it into the
housing.
7. Mount the three screws as shown above.
Tighten them to a torque according to
exploded view.