3. 

 When should the 

pistons be replaced?

This section provides guides on how to deter-

mine whether the pistons of APP 11-13 and 16-22 

are worn and should be replaced. 

Note: If the pistons break down, the pump will 

suffer a disastrous breakdown.

In case of doubt – the pistons must be replaced. 

If any worn pistons are found, all pistons must be 

replaced.

The pictures below are meant as guideline for 

evaluating the wear of the sliding surface.

1. 

 No wear or cavitation of the piston shoe.  

New inspection is required within  

4,000 hours.

2. 

 Cavitation of the piston shoes. 

New inspection is required within  

2,000 hours.

3. 

 Cavitation of the piston shoes. 

All pistons must be replaced within 

the next 1,000 hours.

Содержание APP 11-13

Страница 1: ...ro solutions com Instruction Changing pistons APP 11 13 and APP 16 22 MAKING MODERN LIVING POSSIBLE...

Страница 2: ...conditions of absolute cleanliness Tools needed are 13 mm combination wrench 6 mm allen key Service kit see parts list 521D0941 1 Disconnect the pump from the system or close all connection pipes wate...

Страница 3: ...combination wrench and turn each screw a couple of rounds at the time to ensure the swash plate is loosened as straight backwards as possible Note There is nothing to hold the swash plate 4 Remove th...

Страница 4: ...se surface Warning Ensure that the piston shoes and piston surfaces are not damaged or scratched during removal 8 Remove the retainer plate 9 Inspect the piston bushings in the cylinder barrel for scr...

Страница 5: ...viced in conditions of absolute cleanliness All parts must be absolute clean before mounting 1 Carefully push the retainer plate in place 2 Ensure that the retainer plate is oriented correctly with it...

Страница 6: ...Bleed the pump 10 Follow the start up procedure see instruction 180R9223 6 Mount the 3 screws as shown below Turn each screw a couple of rounds at the time to ensure the swash plate is pulled as stra...

Страница 7: ...he pump will suffer a disastrous breakdown In case of doubt the pistons must be replaced If any worn pistons are found all pistons must be replaced The pictures below are meant as guideline for evalua...

Страница 8: ...e right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications a...