FT1380P Target Settings For Match Mate Plus Hoses 

FT1380P Target Settings For MatchMate Plus Hoses

GH663

Die  

Cage

Target  

Setting

GH793

Die  

Cage

Target  

Setting

GH194

Die  

Cage

Target  

Setting

-4

-M150

0.834

-4

-M150

0.703

-4

-M150

0.836

-6

-M180

0.751

-6

-M210

0.884

-6

-M180

0.772

-8

-M240

0.912

-8

-M240

0.792

-8

-M240

0.907

-12

-M320

0.949

-10

-M280

0.850

-10

-M240

0.652

-16

-M370

0.620

-12

-M320

0.880

-12

-M320

0.935

-16

-M370

0.521

-16

-M370

0.608

-20

-M465

0.647

-20

-M420

0.585

GH781

Die  

Cage

Target  

Setting

GH493

Die  

Cage

Target  

Setting

GH195

Die  

Cage

Target  

Setting

-4

-M150

0.735

-6

-M210

0.749

-4

-M150

0.732

-6

-M210

0.930

-8

-M280

0.933

-6

-M210

0.882

-8

-M240

0.827

-10

-M280

0.691

-8

-M240

0.790

-10

-M280

0.887

-12

-M320

0.714

-10

-M280

0.845

-12

-M320

0.960

-16

-M370

0.323

-12

-M320

0.877

-16

-M370

0.675

-20

-M465

0.440

-16

-M370

0.493

-20

-M465

0.781

-20

-M465

0.544

Содержание Aeroquip FT1380P

Страница 1: ...Operator s Manual Aeroquip by Danfoss Procrimp FT1380P Crimp Machine...

Страница 2: ...cifications 3 Accessories 3 Setup and Assembly lnstructions 4 Operating Instructions Loading and Unloading Die Cages 5 Establishing Crimp Setting 5 Crimping Procedures 6 Calibration Maintenance Mainte...

Страница 3: ...ot rest your hand on the crimp ring Keep your hands clear of all moving parts Do not allow anyone other than the oper ator close to the equipment while it is in operation 4 MAINTAIN DIES WITH CARE Die...

Страница 4: ...p Internal skive fittings Hose that requires a positive stop including the following Aeroquip hoses 2807 2808 FC186 FC465 FC469 and FC505 Accessories Die Holder Kit A plate and mounting hardware that...

Страница 5: ...our 1 2 inch lag screws or other suitable fasteners 2 Install the die cage hanger bracket on the back of the crimper base optional 3 Place the pump on the bench to the right of the crimper and remove...

Страница 6: ...may be inserted or removed in this position Establishing Crimp Setting The three digit micrometer display setting determines the crimp diameter for each combination of hose fitting and crimp cage The...

Страница 7: ...crimped the crimp ring will stop moving indicating the crimp operation is complete Internally a hydraulic valve shifts to divert the fluid back to the reservoir Further pump ing will not result in add...

Страница 8: ...head 3 Insert an FT1380 200 M240 die cage 4 Adjust the micrometer setting to 0 760 5 Center a 1 SB8 socket or TTC 8 fitting without a hose in the die cage holding the socket in place with a pencil or...

Страница 9: ...ip part num ber FT1092 FT1092 is an 8 ounce container that will provide sufficient lubricant for about 5 000 crimps Periodically remove High Efficiency PTFE Grease Danfoss part num ber T 400 G residue...

Страница 10: ...GGG0790000 Hose Assembly not included with FT1380P 1 3 Kit 1 14 2021 6 6S Adapter not included with FT1380P 1 3 Kit 1 15 FT1380P 3 12 Pressure Plata 1 16 1C0190BEEE0160A Hose Assemblv 1 Item Part Numb...

Страница 11: ...1330 2 9 21 FT1330 2 9 2 Die Spring 8 or 16 2 FT1380 2 9 3 FT1380 2 9 2 Front Plate 1 3 FT1330 2 9 13 FT1330 2 9 3 Spring Plate 1 4 FT1330 2 9 55 FT1330 2 9 5 Button Head Cap Screw 4 5 FT1330 2 9 66 F...

Страница 12: ...6 6 M180 0 751 6 M210 0 884 6 M180 0 772 8 M240 0 912 8 M240 0 792 8 M240 0 907 12 M320 0 949 10 M280 0 850 10 M240 0 652 16 M370 0 620 12 M320 0 880 12 M320 0 935 16 M370 0 521 16 M370 0 608 20 M465...

Страница 13: ...ety of equipment and applications around the world We proudly engineer to support a sustainable future for tomorrow To learn more please visit http www danfoss com en about danfoss our businesses powe...

Отзывы: