SPECIFICATION

Power 

Supply 

    : 230Vac, 

50Hz

Switch Action 

 

 

 

 

2 x SPDT, type 1 B

Switch Rating 

 

 

 

 

10 to 253Vac, 50/60Hz, min 10mA, max 10 (4) A

Timing 

Accuracy 

    : ±1 

min/month

Power Reserve   

 

 

 

3 months on fully charged battery

Max. number of switching operations 

 

up to 200 ON or OFF operations per week

Enclosure 

Rating 

    : IP30

Max. 

Ambient 

Temperature 

  : 45°C

Designed to meet  

 

 

 

BS EN60730-2-7

Overall Dimensions (mm)  

 

 

228 wide x 115 high x 50 deep

Control Pollution Situation 

 

 

Degree 2

Ball 

Pressure 

Test 

    : 75°C

Rated 

Impulse 

Voltage 

   : 2.5kV

N

L

6

5

4

3

2

1

THIS WAY UP

Alternative position for 
cable clamp

Aperture for 
cable entry

4 fi xing 
holes

2 cable clamps

3 knock outs for 
surface cable entry

Rating & Model 
label

Terminal Block

Polarised Plug