Item
Description
Wrench size
Torque
QC125
Coil plastic nut
26 mm 12 pt socket
3.5 N•m [2 lbf•ft]
C300
Screws
4 mm internal hex
6.5 N•m [4.75 lbf•ft]
Install the control
1. Using petroleum jelly to retain them, install 4 new seal rings (C200) in the recesses on the control
housing.
2. Install the control assembly onto the endcap using the 4 screws (C300). Torque at 5.4 to 7.5 N•m [4.0
to 5.5 lbf•ft] using a criss cross pattern and retorque the first screw to ensure proper torque retention.
Install the control
C200
C300
P109056
Install auxiliary mounting pad
1. Install the adapter (J080) with new O-rings (J090, J095). Tighten the screws (J100) at 47.5 to 61 N•m
[35 to 45 lbf•ft].
2. Install the coupling (J140) onto the shaft.
Repair Instructions
Series 45 Frame K2 Axial Piston Pumps
Reassembly
34 |
©
Danfoss | April 2017