Orient the housing with the flange facing up. Using snap-ring pliers, remove the snap ring (K010).
Carefully pry out the shaft seal (K020).
If you are unable to pull the shaft seal out, try to push the seal out by going through the inside of the
housing.
P109058
K010
K020
Control
C
CAUTION
If removing the LS or PC spool is not possible, be extremely careful when flipping or relocating the
housing so you do not lose or damage the spool.
PC only
Remove the plug (C103) and O-ring (C103A). Discard the O-ring. Remove the screw (C102). Remove the
spool (C132). Note the orientation of the spool for reinsertion. There may be differences in reinserting
into the same bore. Remove the adjusting screw (C138) and O-ring (C138A). Discard the O-ring. Remove
the springs (C134, C135) along with the spring guide (C133).
Disassemble the PC control
d
C103A
C132
R
C133
C135
C134
d
C138A
C138
C102
E101 193
C103
Repair Instructions
Series 45 Frame K2 Axial Piston Pumps
Disassembly
©
Danfoss | April 2017
AX00000305en-US0101 | 13
Содержание 45 K2 Series