Service Manual
Series 45 J Frame Open Circuit Axial Piston Pumps
520L0607
• Rev AI • Sep 2013
30
If any plugs or fittings are removed from the unit during service, install and torque as indicated
here. This drawing is a composite. Your configuration may differ but here is the appropriate
wrench size and torque:
J041A
J041
K040
K070A
K070
3
/
8
inch
55 - 135 N•m
[40 - 100 lbf•ft]
1
/
4
inch
27 - 47 N•m
[20 - 35 lbf•ft]
K040A
3
/
8
inch
55 - 135 N•m
[40 - 100 lbf•ft]
E101 257
Plug locations, sizes, and torques
Minor Repair (continued)
Plug and fitting sizes and
torques