8. Install two screws (J130) and torque to 44 N•m [32 lbf•ft].
Auxiliary mounting pads
J095
J090
J120
J110
J085
J140
J140
J085
J120
J110
J095
J090
J100 (4pl.)
J085
J095
J100 (4pl.)
J130(2pl.)
P109054
Wrench size and torque
Item
Description
Wrench size
Torque
J085
pad adapter
-
-
J090
O-ring
-
-
J095
O-ring
-
-
J100
cap screw
8 mm internal hex
54 Nm [39 lbf•ft]
J110
cover plate
-
-
J120
O-ring
-
-
J130
screw
9/16 inch
44 N•m [32 lbf•ft]
J140
drive coupling
8 mm internal hex
54 Nm [39 lbf•ft]
Inspection
Inspect sealing surfaces on the endcap and auxiliary pad and make sure that they are clean and free of
contaminants. Inspect the coupling (J140) for any signs of excessive or abnormal wear. Replace all O-
rings. Replace excessively worn parts if necessary.
Assembly
1. Install the adapter (J085) with new O-rings (J090, J095). Tighten the screws (J100) at 75 N•m [55 lbf•ft].