3
Please Note:
This product should only be installed by a qualifi ed
electrician or competent heating installer, and should be
in accordance with the current edition of the IEEE wiring
regulations.
Specifi cation
Power supply
230 Vac ± 15%, 50 Hz
Switching action
1 x SPST, Type 1B
Switch rating
264 Vac, 50/60Hz, 3(1)A
Timing Accuracy
±1 min./month
Power Reserve
Minimum 14 days
Enclosure Rating
IP30
Max. Ambient Temperature
45°C
Dimensions, mm (W, H, D)
102 x 136 x 47
Design standard
EN 60730-2-7
Control Pollution Situation
Degree 2
Rated Impulse Voltage
2.5kV
Ball Pressure Test
75°C
Product specifi cation
Specifi
ca
tion
Installation Instructions