2

Danfoss Randall can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss Randall reserves 
the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without 
subsequent changes being necessary in specifi cations already agreed.

Danfoss Ltd

Ampthill Road, 
Bedford  MK42 9ER.
Telephone: (01234) 364621 Fax: (01234) 219705
Email: [email protected]
Website: www.heating.danfoss.co.uk

  Part No: 7459v18     06/08

INTERNAL WIRING MODEL 102

INTERNAL WIRING MODEL 103

Water

Output

Heating

Output

L

N

Mains

Supply

1

2

3

5

6

HW

W

OFF

NOTE

: Terminals 3 and 6 

MUST

 be linked externally 

(except when voltage free switch contacts are required).

Terminals

Output

L

N

Mains

Supply

1

2

3

5

6

NOTE

Terminals 3 and 6 should (in most instances) be linked externally.

Exceptions are when control circuits are operating at low voltage (e.g. 24 volts) or for certain 

Combination Type Boilers (see Boiler Manufacturers Handbook).

Terminals

CONSTANT

TIMED

OFF

TYPICAL EXTERNAL CIRCUITS

TYPICAL EXTERNAL CIRCUITS

102 Terminals

102 Terminals

L

N

Mains

Supply

 L 

 

N  Boiler

 L 

 

1

2

3

5

6

Pump

N

 

Room
Stat

Com

Call

Link

1) Typical domestic gas or oil fi red system with 

gravity hot water and pumped heating. (If a 

room stat is not requires wire pump L directly to 

terminal 2 on the 102).

2) Fully pumped system with cylinder stat in HW 

circuit and room stat and 2 port spring return 

zone valve in heating circuit.

L

N

Mains

Supply

 L 

 

N

 

Room
Stat

Com

Call

Link

1

2

3

5

6

To Boiler & Pump

N

 

L

 

Motor

HP2 spring return 

zone valve

Blue

 

Grey

Brown

C

1

2

Cylinder Stat L641A

1) Control of Heating Function only (Mains 

Voltage)

Note: If room thermostat is not required 
join timeswitch terminals 1 and 2 with a 

link suitable for full load current).

2) Control of Low Voltage Systems

(e.g. warm air gas valves, low voltage 

burners).

L

N

Mains

Supply

 L  N 

1

2

3

5

6

N

 

Com

Call

Link

L

N

Mains

Supply

1

2

3

5

6

103 Terminals

103 Terminals

Room
Stat

Load

Terminals

Low voltage

supply

Load

Low 

voltage 

room stat

3) Typical gas or oil fi red heating system with 

gravity hot water primary and pumped heating.

4) Typical control of heating when used with 

combination type boilers.

1

2

3

5

6

NOTE: 

Ease of installation can be achieved by using the Danfoss Randall 

Wiring Centre which is obtainable from most Builders Merchants and 
Distributors.

IF A WIRING CENTRE IS USED, follow the installation instructions included 
with the unit and not the wiring diagrams shown on this page.

1

2

3

5

6

L

N

Mains

Supply

N

 

Call

Link

Room
Stat

Pump

Terminals

 L  N 

Boiler

Terminals

L

N

Mains

Supply

N

 

Call

Room
Stat

 Input  Output 

 

L

Boiler Terminals

Com

Com

103 Terminals

103 Terminals

INTERNAL WIRING MODEL 106

1

2

3

5

6

Terminals

4

Water

Priority

Heating

Priority

OFF

L
N

To boiler & pump

Fully pumped system with 3 port (2 way) diverter valve.

 L  N 

Orange not 

connected

(make safe)

If Danfoss Randall HS3 valve is used 

connect valve brown and grey to 

terminal 2 of 106

Room Stat

COM

SAT

CALL

Cylinder Stat

COM

SAT

CALL

L

N

Typical 
External 
Circuit

Honeywell 'W' plan or Satchwell 'K' plan.

Orange

 L  N 