background image

3

© 2009 Danfoss Inc.

Programmable Thermostats 088L5130/5132  

 English

9

  Press the 

OK

 button. The temperature setting will now fl ash in 

the upper part of the display. 

10

  Press the 

Up

 or 

Down

 buttons to set the required temperature.

11

  Press the 

OK

 button. The symbol for the next event (e.g. at 

work) will now fl ash, allowing you to set the time and tempera-
ture for this period of the day by repeating steps 6-12.

12

  Once time and temperature have been set for the four events 

applicable for the 5-day period Monday to Friday, 

Exit

 will fl ash.

13

  Press the 

OK

 button. The next 2 days, 

Sat Sun

, will then fl ash. 

Please note that now only two events (Day and Night) are dis-
played. 

14

  Press the 

OK

 button. The symbol for the fi rst event will fl ash.

15

  Set the time and temperature for this event, and for the following 

event, by repeating steps 6-12.

16

  Finally, select 

Exit

 to exit the 

Program

 for a 5:2 schedule.

PROGRAM

SAT SUN

EXIT

SET TEMP

Quick Set Temperature 

I want to permanently change the temperature for 
the event currently active in the automatic program.

To do so, you must:

1

  Press the 

Up

 or 

Down

 buttons to set the required temperature 

for the event currently active.

2  

Press the 

OK

 button.

The new temperature setting will then be saved and used for this 
event in the future. 

Example: If you change the temperature on a Tuesday morning 
while the thermostat is running a 5:2 program, the new tempera-
ture will apply to all mornings from Monday to Friday.

Adaptive Preheat Feature

I want to ensure that the required temperature has 
already been reached when I get up in the morning 
or come home from work.

To do so, you must activate the adaptive function: 

1

  Press the 

OK

 button to activate the menu.

2

  Press the 

Up

 or 

Down

 buttons until the 

Settings

 option fl ashes.

3

  Press the 

OK

 button.

4

  Press the 

Up

 or 

Down

 buttons until the 

Adaptive

 option 

fl ashes.

5

  Press the 

OK

 button. On or Off will now fl ash in the upper part 

of the display.

6

  Press the 

Up

 or 

Down

 buttons until 

On

 fl ashes.

7

  Press the 

OK

 button.

8

  Select 

Exit

 to exit the option.

Please note:

 The adaptive preheat function is only related to the 

4-event program and only works in connection with going from one 
event to another where the temperature is going to be raised. 

The adaptive preheat feature calculates when the thermostat must 
start the heating system to ensure that the required temperature 
is reached at the set time. Three days after the adaptive preheat 
feature has been activated, it has learned when the heating must 
be switched on to attain the required temperature.

Factory setting: ON

SETTINGS

TIME

DAY

CHILDLOCK

C°/F°

APPLICATION

OFFSET TEMP

READOUT

ADAPTIVE

DISPLAY

FACTORY RESET

EXIT

Manual Mode

I want to temporarily cancel the automatic 4-event 
program and manually select temperature.

To do so, you must use manual mode:

1

 Press the 

OK

 button to activate the menu.

Press the 

Up

 or 

Down

 buttons until the 

Mode

 option fl ashes.

3

 Press the 

OK

 button.

4

  Press the 

Up

 or 

Down

 buttons until 

Man. mode

 fl ashes in the 

upper part of the display. The temperature will begin to fl ash. 

5

  Press the 

Up

 or 

Down

 buttons until the required temperature 

fl ashes.

6

  Press the 

OK

 button.

Please note: 

This feature can be useful for instance if you are go-

ing on holiday and want to maintain a frost protection temperature 
(e.g. 41°F) while you are away.

To return to the automatic 4-event program, you must select Auto. 
Please refer to page 2 for instructions.

MAN. MODE

MODE

Temporary Override

I want to temporarily set a comfort temperature for 
a single event, e.g. because I am not at work one 
day and want to maintain a higher temperature or 
because I am having a party.

To do so, must use override mode:

1

  Press the 

OK

 button twice to activate the menu.

2

  Press the 

Up

 or 

Down

 buttons until the 

Mode

 option fl ashes.

3

  Press the 

OK

 button.

4

  Press the 

Up

 or 

Down

 buttons until 

Override

 fl ashes in the up-

per part of the display. The temperature will begin to fl ash. 

5  

Press the 

Up

 or 

Down

 buttons until the required temperature 

fl ashes.

6  

Press the 

OK

 button.

Содержание 088L5130

Страница 1: ...temperature is reached at the required time After three days the adaptive preheat feature learns when the heating must be switched on First Time Settings The first time you turn on the thermostat time...

Страница 2: ...tions flashes in the upper part of the display 5 Press the OK button Factory setting Auto mode AUTO OVERRIDE MAN MODE MODE SCHEDULE PROGRAM SETTINGS EXIT Step 2 Choosing the weekly schedule for your p...

Страница 3: ...pper part of the display 6 Press the Up or Down buttons until On flashes 7 Press the OK button 8 Select Exit to exit the option Please note The adaptive preheat function is only related to the 4 event...

Страница 4: ...er part of the display 5 Press the Up or Down buttons until the required unit C F flashes 6 Press the OK button 7 Select Exit to exit the option Please note Temperatures are displayed in Celsius with...

Страница 5: ...room thermometer It is possible to adjust the offset by up to 10 C or 18 F Once the offset has been set correctly the thermostat will display the same temperature as the thermometer If for example th...

Страница 6: ...ntil the Reset option flashes 7 Press the OK button 8 Select Exit to exit the option SETTINGS TIME DAY CHILDLOCK C F APPLICATION OFFSET TEMP READOUT ADAPTIVE DISPLAY FACTORY RESET EXIT RESET EXIT Exit...

Страница 7: ...nt les boutons Up hausse ou Down baisse Appuyez ensuite sur le bouton OK pour confirmer l heure Le jour de la semaine clignotera S lectionnez le jour actuel en utilisant les boutons Up hausse ou Down...

Страница 8: ...re souhait e V rification du disjoncteur de fuite la terre int gr La v rification ne peut s effectuer que si le thermostat active le chauffage R glez le point de consigne jusqu ce que le symbole du ch...

Страница 9: ...atin ou quand je reviens du travail Vous devez alors activer la fonction d adaptation 1 Appuyez sur le bouton OK pour activer le menu 2 Appuyez sur les boutons Up hausse ou Down baisse jusqu ce que l...

Страница 10: ...rner au programme automatique 4 v nements vous devez s lectionner Auto Voir la page 2 pour les instructions MAN MODE MODE D rivation temporaire Je veux r gler temporairement une temp rature de confort...

Страница 11: ...pour sortir de l option Le d calage est utilis pour r duire toute diff rence entre le thermostat et un thermom tre de pi ce Il est possible de r gler le d calage jusqu 10 C or 18 F Une fois que le d...

Страница 12: ...boutons Up hausse ou Down baisse jusqu ce que l option Settings r glages clignote 3 Appuyer sur le bouton OK 4 Appuyer sur les boutons Up hausse ou Down baisse jusqu ce que l option Application appli...

Страница 13: ...ts de temp rature heure Quand vous entrez dans les divers menus ils afficheront toujours la derni re valeur s lectionn e Ceci vous permet de v rifier les r glages courants Si vous ouvrez un menu par e...

Страница 14: ...te la hora actual con los botones Up Arriba o Down Abajo Despu s pulse el bot n OK Aceptar para confirmar la hora Entonces parpadear el d a de la semana Seleccione el d a actual con los botones Up o D...

Страница 15: ...el trabajo Cuando regreso a casa y durante la noche Para hacerlo ser necesario realizar los 3 pasos siguientes Paso 1 Seleccione el control de temperatura autom tico 1 Pulse el bot n OK para activar...

Страница 16: ...onces se guardar el nuevo ajuste de temperatura y se utilizar en el futuro para este evento Ejemplo Si usted cambia la temperatura para el martes en la ma ana mientras el termostato ejecuta un program...

Страница 17: ...autom tico de 4 eventos deber selec cionar Auto La p gina 2 incluye instrucciones MAN MODE MODE Anulaci n temporal Deseo establecer temporalmente una temperatura de confort para un solo evento por ej...

Страница 18: ...en la parte superior de la pantalla El submen Readout contiene tambi n informaci n sobre la versi n del Software y sobre el tipo de control Ambiente Piso Regulador o L mite ambiente para la Aplicaci n...

Страница 19: ...o no encendido apagado Ver la temperatura establecida o no encendido apagado Adem s puede decidir si la temperatura mostrada es la temperatura ambiente la temperatura de piso si se utiliza un sensor...

Страница 20: ...reserved Danfoss Inc Toronto Toll Free 866 676 8062 Phone 905 285 2050 Fax 905 285 2055 www LX Danfoss com DanfossLX BRINGING WARMTH TO LIFE Mensajes de error E0 Error interno Cambie el termostato E1...

Отзывы: