Installation manual for DM700 ECDIS
Copyright Danelec Marine A/S
MAN11805-10
Page 35/67
7.
To close the
Line
monitor
panel, press the
[Close]
button: the panel is closed.
6.4.3 Deleting a sensor
1.
Go to
Main Menu
Settings
Vessel
Sensors
: the
Sensors
panel opens.
2.
Select the sensor you want to delete: the sensor parameters panel opens.
3.
Press the
[Delete]
button.
4.
You are prompted for the MASTER password. (use the SERVICE password)
6.4.4 Available sensors
In the table below you can see a list of sensors available for registration in the ECDIS with their
NMEA sentences which can be processed in the ECDIS.
Sensor
Messages
Image
Position sensor
GLL VTG RMC GGA ZDA DTM
GNS TXT
Heading
HDT VHW THS ROT VBW TXT
Speed through water
VHW VBW TXT
Depth sensor
DBT DPT TXT
Wind sensor
MWV MWD TXT
AIS
VDM VDO TXT