IMPORTANT MAINTENANCE NOTES
Check the QuicKART daily, for safe operation.
Improper use or operation of the QuicKART, or the lack of proper maintenance, may
result in decreased performance or damage to the QuicKART. The following parts of the
QuicKART need regular and routine maintenance.
1. Batteries
- Add distilled water as necessary. Water levels should be checked
monthly
.
2. Tires
– Tires are solid (foam filled). Check
weekly
for wear.
3. Rear Swivel Wheel Bearing
– Grease every
6 months
(grease gun compatible).
If at any time the QuicKART does not operate correctly, immediately turn it off and
remove the key to prevent further operation.
Immediately report any malfunctions to
the store manager responsible for the QuicKART and Dane Technologies at 1-888-544-
7779.