PRODUCT SAFETY

 

 

This product is manufactured with the highest standards and is double checked  
in our quality control department for reliability in the  "HIGH VOLTAGE" section. 
 
CAUTION 
Never remove any panels, or open this equipment. No user serviceable parts  
inside. 
Equipment power supply must be grounded at all times. 
Only use this product as described, in user manual or brochure. 
Do not operate this equipment in high humidity or expose it to water or other  
liquids. 
Check the AC power supply cable to assure secure contact. 
Have your equipment checked yearly by a qualified dealer service center. 
Hazardous electrical shock can be avoided by carefully following the above  
rules. 
 
PLEASE READ THE FOLLOWING INFORMATION 
 
Especially in sound equipment on stage the following information is essential to know.  
An electrical shock is caused by voltage and current, actually it is the current that causes the 
shock.  
In practice the higher the voltage the higher the current will be and the higher the shock. 
But there is another thing to consider and it is resistance.  
When the resistance in Ohms is high between two poles, the current will be low and vice versa. 
All three of these; voltage, current. and resistance are important in determining the effect of an 
electrical shock.  

However, the severity of a shock primarily determined by the amount of current flowing through 
a person. 

 

A person can feel a shock because the muscles in a body respond to electrical current and 
because the heart is a muscle it can affect, when the current is high enough.  
Current can also be fatal when it causes the chest muscles to contract and stop breathing. At 
what potential is current dangerous.  
Well the first feeling of current is a tingle at 0.001 Amp of current.  
The current between 0.1 Amp and 0.2 Amp is fatal. 
Imagine that your home fuses of 20 Amp can handle 200 times more current than is necessary to 
kill.  How does resistance affect the shock a person feels.  
A typical resistance between one hand to the  other in "dry" condition could well over  
100,000 Ohm.  

 
If you  are playing  on stage your body is perspiring extensively and your body resistance is 
lowered by more than 50%.  This is a situation in which current can easily

 

flow.

  

Содержание Telephone Hybrid-2

Страница 1: ...TELEPHONE HYBRID 2 USER MANUAL ...

Страница 2: ... All functions are self explanatory and you will certainly appreciate the ergonomics of this design We are confident that you will be using the Telephone Hybrid for many years to come and wish you a lot of success with your operation With kind regards Duco de Rijk PRESIDENT D R ELECTRONICA WEESP B V Rijnkade 15B 1382 GS WEESP HOLLAND The Netherlands Phone 0294 418 014 Fax 0294 416 987 Website http...

Страница 3: ... telephone line connection a handset connection and separate connectors for audio input and output from a broadcast mixer or other professional audio source A large proportion of D R hybrids are used in radio and television broadcasting applications allowing external callers to be connected to the studio mixing console Most of the other units are supplied to communication operations allowing extre...

Страница 4: ...f the mixer SYSTEM DESCRIPTION A large ring button enables you to pick up the line from the unit itself or from your mixer when connected via its GPIO to the telephone Hybrid When a call comes in it lights up green in the rhythm of the ring When the line is picked up by pushing the button it turns into red When it starts blinking red the line connection is lost Both levels of receive and send can ...

Страница 5: ...s in their mid position If a local phone is connected originate a call to aremote side If no local phone is present someone at a remote site must call you When a call comes in the large ring BUTTON on the left side of the unit lights up green in the rhythm of the ring When the line is picked up by pushing the button it turns into red When it starts blinking red the line connection is lost If you a...

Страница 6: ...aking the caller s signal is reduced then INPUTS OUTPUTS SEND XLR FEMALE TYPE CONNECTION Pin 1 Screen Audio ground Pin 2 Phase Audio Pin 3 Non phase Audio RECEIVE XLR MALE TYPE CONNECTION Pin 1 Screen Audio ground Pin 2 Phase Audio Pin 3 Non phase Audio SUB D 9 AUDIO GPIO GPIO SEND RECEIVE FUNCTION CONNECTION Pin 6 Receive Audio Pin 2 Receive Audio ground Pin 7 Send Audio Pin 3 Send Audio Pin 8 Se...

Страница 7: ...e line In out Pin 4 n c LINE LINE RJ12 FUNCTION CONNECTION Pin 1 n c Pin 2 A telephone line In out Pin 3 B telephone line In out Pin 4 n c SPECIFICATIONS Audio Inputs SEND Impedance 10k Ohm electronically balanced Common mode rejection 40dB Maximum input level 26dBu Nominal input level 4 dBu Frequency response 20Hz 15kHz 3dB variable via HC and LC filters Connectors XLR type 3 pin female Gain rang...

Страница 8: ...e impedance Nominally 600 ohm Telephone line impedance range 300 ohm to 1500 ohm Connectors XLR type 3 pin male Gain range send control 6dB to 20dB GENERAL Distortion Less than 0 1 0dBu out Power supply 115v 230 v AC 50 60Hz factory set NOT do this yourself Power consumption 10VA Maximum Dimensions 1 HE front panel 482x44mm Frame 430x41x175mm width x height x depth Weight 2 2 kg net excl packing I...

Страница 9: ...ccordance with the following standards or standardized documents EN 50081 1 EN 55013 A 12 EN 50082 1 EN 55022 EN 60065 EN 61000 3 2 EN 55020 EN 61000 3 3 Supplementary Information The products herewith complies with the requirements of the EMC Directive 89 336 EWG and 73 23 EWG as amended by the CE Marking Directive 93 68 EEC 1993 Duco de Rijk August 2003 president D R Electronica Weesp b v Rijnka...

Страница 10: ...ck But there is another thing to consider and it is resistance When the resistance in Ohms is high between two poles the current will be low and vice versa All three of these voltage current and resistance are important in determining the effect of an electrical shock However the severity of a shock primarily determined by the amount of current flowing through a person A person can feel a shock be...

Страница 11: ...um it will create a very hazardous situation for the performing musician Always earth all your equipment by the grounding pin in your mains plug Hum loops should be only cured by proper wiring and isolation input output transformers Replace fuses always with the same type and rating after the equipment has been turned off and unplugged If the fuse blows again you have an equipment failure do not u...

Страница 12: ...Manual page 12 TELEPHONE HYBRID 2 SERVICE MANUAL ...

Страница 13: ......

Страница 14: ......

Страница 15: ...VC 1 0000 st 130 10700625 Kartelring M3 buitenvertand 2 0000 st 170 10450090 Knob SiF Rub Gry TPN110 006 13 4 0000 st 50 10600701 Mains inlet SKT MS3 FR MS3 1 0000 st 60 10600498 Mains lead 3 core Euroconnecto 1 0000 st 70 10700610 Moer M3 4 0000 st 200 10650383 Montagesnoer 1 5mm blauw 35 0000 cm 190 10650391 Montagesnoer 1 5mm bruin 35 0000 cm 210 10650388 Montagesnoer 1 5mm groen 30 0000 cm 10 ...

Страница 16: ...st 760 10400292 Elco 100uF 25V rad R5 0 8 0000 st 770 10400293 Elco 220uF 63V radial R5 0 2 0000 st 780 10400297 Elco 1000uF 40V axial 30x12 5 2 0000 st 750 10400284 Elco 10uF 50V radial R5 0 1 0000 st 790 10600505 Header 2p pin 0º sngl 1 0000 st 830 10600474 Header 3p 0º 3 96 1 0000 st 910 10600513 Header 5P Lock 0º 2 54 2 0000 st 800 10600514 Header 5P Lock 90º 2 54 1 0000 st 950 10600506 Header...

Страница 17: ...k 5 1 4W 2 0000 st 350 10350859 Resistor 24k3 1 1 4W 1 0000 st 360 10350861 Resistor 28k7 1 1 4W 1 0000 st 140 10350713 Resistor 47E 5 1 4W 8 0000 st 370 10350749 Resistor 47K 5 1 4W 1 0000 st 380 10350751 Resistor 68k 5 1 4W 1 0000 st 150 10350717 Resistor 100E 5 1 4W 4 0000 st 390 10350758 Resistor 270k 5 1 4W 1 0000 st 400 10350760 Resistor 390k 5 1 4W 1 0000 st 160 10350725 Resistor 470E 5 1 4...

Отзывы: