212-0024-13SS
8
December 19th, 2023
Setting up the PDU-13SS
Low Voltage Shutdown Setup
The PDU-13SS factory default LOW VOLTAGE SHUTDOWN value is set to 11.5 VDC for all outputs.
Note: - When the vehicle battery voltage drops below the pre-set voltage all the outputs will turn off.
Timed Shutdown Setup
The time delay for the timed outputs is user selectable and is set by a 4 position miniature
switch that is accessible through the top cover of the PDU-13SS. The delay time can range
from 30 minutes to 240 minutes. This function is triggered by turning the vehicle ignition
“OFF”.
When the selected time has elapsed power to all timed outputs will be shut “OFF”. If during
the timing cycle the ignition is turned back on the timer will reset and the time cycle will re-
start when the ignition is turned off again.
To set the time delay follow these steps:
1. Locate the dip switch on the PDU-13SS.
2. Refer to the attached label or Table 1 below to determine the switch settings.
3. Use a pen tip or other suitably small tool to set the switches. This will select the time incre-
ments to the output off time delay.
TIME
SW-1
SW-2
SW-3
SW-4
30 MIN.
OFF
OFF
OFF
ON
60 MIN.
OFF
OFF
ON
OFF
120 MIN.
OFF
ON
OFF
OFF
240 MIN.
ON
OFF
OFF
OFF