Страница 1: ...GSM HYBRID MANUAL v1 1 D R Electronica B V Rijnkade 15B 1382GS Weesp The Netherlands Phone 31 0 294 418014 Fax 31 0 294 416987 Website http www d r nl E Mail info d r nl ...

Страница 2: ...7 3 1 INSTALLATION 8 3 2 FEATURES 12 3 3 SETTINGS 15 4 GETTING STARTED 16 4 1 HARDWARE SETUP 16 4 2 MAKING CALLS 17 4 3 RECEIVING CALLS 17 5 SPECIFICATIONS 18 5 1 AUDIO INPUT SEND 18 5 2 AUDIO OUTPUT RECEIVE 18 5 3 GENERAL 18 6 DIMENSIONS 19 7 SUMMARY 19 8 ELECTROMAGNETIC COMPATIBILITY 20 9 DECLARATION OF CONFORMITY 20 10 PRODUCT SAFETY 21 11 CAUTION 21 ...

Страница 3: ...ry because of the natural recognition of all functions on the user interface All functions are self explanatory and you will certainly appreciate the ergonomics of this design We are confident that you will be using the GSM Hybrid for many years to come and wish you a lot of success with your operation With kind regards Duco de Rijk MD ...

Страница 4: ...also facilitate two way communication down a single telephone connection With the D R GSM Hybrid you can add a simple and effective wireless interface that your reporters can call With features like HD voice Echo canceling digital EQ and application control over USB on your PC it is a nice tool to expand the communication possibilities of your studio with your reporters in the field The GSM Hybrid...

Страница 5: ...t and output gain adjust Phone dialing Number recognition GSM signal strength indicator RSSI 2 1 Front panel Antenna Both antenna s assure you of an uninterrupted connection with the nearest GSM tower SIM Card In this slot you insert a mini sim card available from your favorite provider CONNECT BUTTON RING Connect switch to connect and disconnect calls from the GSM network It can be remotely drive...

Страница 6: ...puts and Outputs 2 3 1 RECEIVE from caller XLR MALE TYPE CONNECTION Pin 1 Screen Audio ground Pin 2 Phase Audio output Pin 3 Non phase Audio output 2 3 2 SEND to caller XLR MALE TYPE CONNECTION Pin 1 Screen Audio ground Pin 2 Phase Audio output Pin 3 Non phase Audio output 2 3 3 GPIO GPO FUNCTION CONNECTION Tip Pull down 47 ohm to ground Ring Pull up 5 volt via 10kohm Sleeve No Not connected GPI F...

Страница 7: ... to configure and control the GSM Hybrid Input and output levels can be configured in the Settings menu Making a call can be done with the dialpad window The application is also an indicator for SIM card status call status and input and output level PPM meters ...

Страница 8: ...software from http www d r nl wiki dokuwiki doku php id software start 2 Double click on the installer file GSM Hybrid Control Vx x x x Setup exe and click Next 3 Select the destination location where GSM Hybrid Control should be installed and press Next ...

Страница 9: ...9 4 Select a start menu folder for the program s shortcut and click Next 5 Select if a desktop icon should be placed on your desktop and press Next ...

Страница 10: ...10 6 Press Install to start with the installation 7 Wait while the setup installs all the required files on your computer ...

Страница 11: ...11 8 Click Finish to exit the setup procedure ...

Страница 12: ...on in order to view their content in the Main Window More icons in the Menu toolbar are added in the future to give you even more options to control Dialpad The Dialpad is the trivial selection when using the GSM Hybrid Control application With this selected you can make calls by choose the number on the dialpad and press the green call button to initiate a call The C button clears the entered num...

Страница 13: ...ontrol The Call Control contains the trival call and end call buttons respectively green and red colored Pressing the green call button dials the selected number in the dialpad window Pressing the red button will disconnect any active call or reject an incoming call The eight small quick call buttons are for calling a phonenumber stored under one of the memory locations 1 till 8 3 2 5 Activity Win...

Страница 14: ...ctive conversation connection is established the call status change to TALKING and a timer is directly started indicating the elapsed time The number field contains the number you are connected to The codec field contains the used codec for the current connection NB stands for Narrow Band 300Hz 3000Hz and WB for Wide Band 300Hz 8000Hz also called HD voice The GSM Hybrid automatically choose the be...

Страница 15: ... from the Settings menu RECEIVE This is the signal we receive from the caller and is feed to the XLR male output connector Output volume can be adjusted from 0 100 SEND This is the signal we send to the caller and is provided at the XLR female input connector Input gain can be adjusted from 12dB 35 25dB with an additional boost of 20dB ...

Страница 16: ...e to a line input of the mixing console Note that this signal is NOT to be send to the output where the Hybrid s input is connected to So in case of use of an Aux send this local channel Aux send needs to be turned off In case of use of a clean feed buss this input channel needs to be disconnected from the cleanfeed buss 4 OPTIONAL Position RECEIVE and SEND controls of the mixer in their mid posit...

Страница 17: ... the top bar 5 Click the DialPad icon on the Menu and enter the phone number you want to call 6 Press the green call button to make the call 4 3 Receiving calls 1 Make sure you have properly setup all hardware connections 2 Power the GSM Hybrid with the deliverd power supply 12VDC and wait for the ON led to become stable green 3 Start the GSM Hybrid Control Software double click the icon on your d...

Страница 18: ...ectronically balanced Common mode rejection 40dB Maximum output level 21 5dBu Nominal output level 6 dBu Bandwidth to telephone line 50Hz 7kHz 3dB ref 1 kHz Connectors XLR type 3 pin male 5 3 General GENERAL Distortion Less than 0 1 0dBu out Power supply 100 240 volt AC 50 60Hz to 12Volt 1Amp Power consumption 10VA Maximum Dimensions 1 HE front panel 241mm x 44mm 1HE USB USB 1 1 GPO Opto Fet 60V 5...

Страница 19: ... Phone 0031 0 294 418 014 Fax 0031 0 294 416 987 Website http www d r nl E mail mail d r nl 7 SUMMARY We hope this manual has given you sufficient information to use this new GSM Hybrid in your studio If you require more info please contact your local dealer or send us an email at mail d r nl and we will answer your email within 24 hours during weekdays In case you have bought this product from a ...

Страница 20: ...shielded interconnecting cables 9 DECLARATION OF CONFORMITY Manufacturer D R Electronica B V Rijnkade 15B 1382 GS Weesp The Netherlands declares that this product Product AIRLITE Model n a Installed options none passed the following product specifications Safety IEC 60065 7th ed 2001 EMC EN 55013 2001 A1 EN 55020 1998 Supplementary Information The product passed the specifications of the following...

Страница 21: ...following the above rules Ground all equipment using the ground pin in the AC power supply cable Never remove this pin Ground loops should be eliminated only by use of isolation transformers for all inputs and outputs Replace any blown fuse with the same type and rating only after equipment has been disconnected from AC power If problem persists return equipment to qualified service technician Alw...