6.1. Header area - Device
(from left to right):
Power on indicator
Yellow
Indicates the start up phase of the power supply.
Green
Indicates that the unit is switched on.
Red
Indicates a device error.
Device view button
The device name and the output mode are displayed. This button
provides direct access to the Device setup screen.
ID
The Remote «ID» is displayed. This navigation button also provides
direct access to the Remote subscreen.
Power button
The «Power» button provides the following functions:
Cancel the sequence.
Mute all
Master mute.
To unmute the channels, use the individual Channel
mute buttons.
Standby
In Standby mode the device idles drawing minimal
power consumption. Only the most essential
functions are provided. The screen and network
remain functional.
6.2. Data area - Channel strip(s)
The data area features the actual channel strips starting with the
input connector and then following the real signal flow from left to
right. All vital information is displayed. This includes:
–
Input signal present (ISP)
–
Input routing
–
Channel configuration,
–
Controller output signal (OSP)
–
Channel mute buttons and status.
–
Error messages
d&b D80 Manual 1.8 en
27
Содержание D80
Страница 1: ...D D80 Manual 1 8 en ...
Страница 32: ...Device setup access chart Hierarchy level 9 Device setup d b D80 Manual 1 8 en 32 ...
Страница 50: ...Channel setup access chart Hierarchy level 10 Channel setup d b D80 Manual 1 8 en 50 ...
Страница 79: ......
Страница 80: ...D2020 EN 01 03 2015 d b audiotechnik GmbH www dbaudio com ...