background image

 

Explanation of graphical symbols

The lightning symbol within a triangle is intended to

alert the user to the presence of uninsulated

"dangerous voltages" within the unit’s chassis that may

be of sufficient magnitude to constitute a risk of electric

shock to humans.

 

The exclamation point within a triangle is intended to alert

the user to the presence of important operating and

service instructions in the literature accompanying the

product.

Before using this product, carefully read the

applicable items of the following safety

instructions.

 

 

1. Keep these instructions for future reference.
2. Read these instructions.
3. Heed all warnings.
4. Follow all instructions.
5.

WARNING!

To reduce the risk of fire or electric shock:

– Do not expose the rack assembly to rain or moisture.
– Keep water or other liquids away.
– Do not place liquid filled containers, for example

beverages, on top of the rack assembly.

– Do not operate the rack assembly while it is wet or standing

in liquid.

 

6. Do not use the rack assembly if its mains power cord is

damaged or frayed.
Protect the power cord from being walked upon or pinched,

particularly at the plugs and the point where it exits from the

rack assembly.

7. Use the mains plug of the rack assembly as the disconnecting

device and keep it readily accessible.

8. Lay all cables connected to the rack assembly carefully so that

they cannot be crushed by vehicles or other equipment and

that no one can either step on them or trip over them.

9. Unplug the rack assembly during lightning storms or when

unused for long periods of time.

IMPORTANT SAFETY INSTRUCTIONS

 

d&b Z5601.002 Manual 1.2 en

3

Содержание Z5601.002

Страница 1: ...D Z5601 002 Manual 1 2 en ...

Страница 2: ...larly check the d b website for the latest version of this document When reselling this product hand over this document to the new owner If you supply d b products please draw the attention of your customers to this document Enclose the relevant documents with the systems If you require additional documents for this purpose you can order them from d b d b audiotechnik GmbH Co KG Eugen Adolff Str 1...

Страница 3: ...electric shock Do not expose the rack assembly to rain or moisture Keep water or other liquids away Do not place liquid filled containers for example beverages on top of the rack assembly Do not operate the rack assembly while it is wet or standing in liquid 6 Do not use the rack assembly if its mains power cord is damaged or frayed Protect the power cord from being walked upon or pinched particul...

Страница 4: ...NS OUTPUTS 10 4 Z5578 LS connector panel 6 x NL8 2 x LKA25 11 4 1 Intended use 11 4 2 4 CH OUTPUTS 11 4 3 12 CH OUTPUT 12 5 Z5604 I O Panel 13 5 1 Intended use 13 5 2 Overview 13 5 2 1 INPUT 13 5 2 2 INPUT LINK 13 5 2 3 Remote network option 13 6 DN1 Ethernet switch 14 6 1 Overview 14 6 2 Mains connection 14 6 3 Front panel 14 6 3 1 ETH 9 ETH 11 14 6 3 2 Mode selection 15 6 3 3 LED indicators 15 6...

Страница 5: ...I O panel Z5604 which serves as a connector interface for both analog and digital audio signals 1 2 Scope of supply Before starting up please verify the shipment for completeness and proper condition of the items If there is any sign of obvious damage do not operate the rack assembly and contact your local dealer from whom you received it Pos Qty d b Code Description 1 1 Z5601 002 Touring rack ass...

Страница 6: ...Dimensions and weight Height x width x depth 1060 x 600 x 780 mm 41 73 x 23 6 x 30 7 Total weight 1x DN1 included 179 kg 394 lb d b Z5601 002 Manual 1 2 en 6 ...

Страница 7: ...ent space of 0 5 m 1 6 ft at the front and rear of the touring rack to ensure adequate cooling airflow CAUTION Risk of personal injury and or damage to material due to possible tipping over To avoid possible tipping over do not move stacked touring racks Do not stack Z5601 002 Touring rack assemblies The rack assemblies can be positioned side by side They can also be combined with Z5600 D40 or Z55...

Страница 8: ...k assembly that produces an opposing airflow observe the following restrictions Do not stack D12 Touring racks or any other rack assemblies with opposing airflow on top of the Z5601 002 Touring rack Z5601 002 and the D12 Touring rack assemblies can be positioned side by side d b Z5601 002 Manual 1 2 en 8 ...

Страница 9: ... and replace it before further use Do not connect or disconnect the CEE mains connector under load or live Please ensure the mains connector is accessible at any time to disconnect the unit in case of malfunction or danger Apart from the six fixed single phase mains power lines 6 x MAINS TO AMPS 230 V for the internal mains power supply of the amplifiers the Z5606 000 Mains power distributor is su...

Страница 10: ...ns outputs powerCON TRUE 1 TOP sockets one on the front panel and three on the rear panel is provided One of these sockets is used to apply mains supply for the DN1 device The remaining sockets are intended for the connection of low current devices such as notebooks or additional Ethernet switches The sockets are equipped with dedicated circuit breakers on the front panel 16 A C Frame type d b Z56...

Страница 11: ... connectors are only intended as an interface to loudspeaker multicores such as the d b Z5343 xxx and breakout adapters such as the d b Z5347 xxx Do not connect any loudspeaker cabinets neither passive nor active systems to the 4 CH OUTPUTS connectors otherwise there is a risk of damaging the loudspeaker components or the amplifier Each of the 4 CH OUTPUTS connectors represents the 4 CHANNEL OUTPU...

Страница 12: ...aker connector panel carries the output signal of twelve 12 amplifier channels The assignment of the respective amplifiers to the corresponding connector is shown in the graphic opposite Pin equivalents of the LKA25 connectors and the corresponding 4 CHANNEL OUTPUT NL8 connector of the respective amplifier are listed in the following table 12 CH OUTPUT AMP 1 2 3 12 CH OUTPUT AMP 4 5 6 LKA25 NL8 Am...

Страница 13: ...s to be fed to the amplifier 5 2 2 INPUT LINK The INPUT LINK section represents the link output connectors of the last third sixt amplifier and allows the linking of further system racks 5 2 3 Remote network option You can daisy chaining the rack assemblies within a remote network using the enclosed rack link cable Z5333 001 For remote purposes via Ethernet OCA it is strongly recommended to use th...

Страница 14: ... accessible at any time to disconnect the unit in case of malfunction or danger Before connecting the device to mains voltage check that the mains voltage and frequency correspond to the specifications on the rating label above the mains connector socket on the rear panel of the unit A mains connector socket 1 is fitted on the rear panel and an appropriate power cord 1 1 is supplied 6 3 Front pane...

Страница 15: ...eave the Configuration mode and switch back to normal display mode Note Without an DHCP server in LinkLocal IP mode IP adress range in primary mode 169 254 xxx IP adress range in secondary mode 172 31 xxx Reset mode The remote reset function resets all settings related to remote communication to factory defaults To reset the DN1 device to defaults proceed as follows 1 Select and hold the MODE butt...

Страница 16: ...vity max 1 Gbit Network activity max 100 Mbit Primary AVB network detected Device in PRI network mode Secondary AVB network detected Device in SEC network mode Active PoE supply LED off Normal operation No active connection No AVB network information No PoE enabled device connected LED flashing Traffic PoE Error 6 4 Rear panel ETH 1 ETH 8 The DN1 device provides a RJ45 8 port panel at the rear of ...

Страница 17: ...Mains power connection and internal mains supply distribution 7 Rack wiring diagrams d b Z5601 002 Manual 1 2 en 17 ...

Страница 18: ...Internal 4 CHANNEL OUTPUT wiring d b Z5601 002 Manual 1 2 en 18 ...

Страница 19: ...Internal analog audio INPUT and LINK wiring d b Z5601 002 Manual 1 2 en 19 ...

Страница 20: ...Internal digital audio INPUT and LINK wiring d b Z5601 002 Manual 1 2 en 20 ...

Страница 21: ...Internal Ethernet network wiring d b Z5601 002 Manual 1 2 en 21 ...

Страница 22: ......

Страница 23: ...D2761 EN 01 06 2022 d b audiotechnik GmbH Co KG www dbaudio com ...

Отзывы: