CAN-Bus network

CAN

Represents the CAN input of the first amplifier

while the other amplifiers are linked within the

rack.

CAN LINK

Represents the CAN output of the last

amplifier.

TERMINATE/

LINK

The built-in termination switch allows two

settings:
1.

LINK: In system racks, at the start of and

within a CAN-Bus segment, set the switch

to LINK.

2.

TERMINATE: On the last system rack of

a CAN-Bus segment, set the switch to

TERMINATE

Note: A detailed description of remote control via the d&b

Remote network (CAN-Bus) is given in the technical

information TI 312 (d&b code D5312.EN) which can be

downloaded from the d&b website at 

www.dbaudio.com

.

5.3. Z5333 Rack Link
The rack link cable allows multiple system racks to be linked

together.

It is suitable for both analog and digital audio signals as well as

for network wiring (Ethernet or CAN-Bus networks).

Technical specifications

Audio connector

2 x XLR female to 2 x XLR male

with color markup

Audio signal capability

Analog

Digital AES3

Network connector

etherCON

Network cable

CAT 5E STP

Length

2 m / 6.5 ft

I/O panel, rack link example:
2ch Analog audio and CAN

 

d&b Z5576.000 Manual 1.1 en

15

Содержание Z5576.000

Страница 1: ...D Z5576 000 Manual 1 1 en...

Страница 2: ...d b website for the latest version of this manual When reselling this product hand over this manual to the new owner If you supply d b products please draw the attention of your customers to this man...

Страница 3: ...8 3 2 1 MAINS IN 8 3 3 Front panel 9 3 3 1 MAINS 9 3 3 2 AUXILIARY MAINS OUTPUTS 9 4 Z5578 LS connector panel 6 x NL8 2 x LKA25 10 4 1 Intended use 10 4 2 ETH POE INCLINOMETER 10 4 3 4 CH OUTPUTS 11 4...

Страница 4: ...peaker connector panel Z5578 In addition the Z5578 loudspeaker connector panel incorporates a POE Power Over Ethernet enabled etherCON RJ 45 connector for the direct connection of an inclinometer Also...

Страница 5: ...19 frame Including 2 1 Z5577 000 Mains power distributor 32 A CEE 3 1 Z5578 000 LS Connector panel 2 x LKA 25 6 x NL8 4 6 Z2710 D80 Amplifier 5 1 Z5338 I O Panel 6 1 Z4010 DS10 Audio Network Bridge 7...

Страница 6: ...rack to ensure adequate cooling airflow Make sure both the front and rear doors are opened and pushed into their park position to provide sufficient cooling Do not stack Z5576 000 Touring rack assembl...

Страница 7: ...rack assembly that produces an opposing airflow observe the following restrictions Do not stack D12 Touring racks or any other rack assemblies with opposing airflow on top of the Z5576 000 Touring rac...

Страница 8: ...do not use the unit and replace it before further use Do not connect or disconnect the CEE mains connector under load or live Please ensure the mains connector is accessible at any time to disconnect...

Страница 9: ...e available Three sockets are mounted on the front and four sockets on the rear panel Two of the rear sockets are used to provide mains supply for the POE injector device and the DS10 The remaining so...

Страница 10: ...o feed an inclinometer which is integrated in the flying frame for vertical aiming of the entire array E8106 POE Injector device In connection with the ETH POE INCLINOMETER socket a corresponding IEEE...

Страница 11: ...eg 4 4 12 CH OUTPUT Two 12 CH OUTPUT multipin connectors LKA25 are provided to allow efficient system wiring using the d b MC24 multicore system Z5328 xxx MC24 LKA25 F M Multicore Z5325 000 Break out...

Страница 12: ...NL8 Amplifier A 1 AMP 1 A 1 AMP 4 B 1 B 1 C 2 C 2 D 2 D 2 E 3 E 3 F 3 F 3 G 4 G 4 H 4 H 4 I 1 AMP 2 I 1 AMP 5 J 1 J 1 K 2 K 2 L 2 L 2 M 3 M 3 N 3 N 3 O 4 O 4 P 4 P 4 Q 1 AMP 3 Q 1 AMP 6 R 1 R 1 T 2 T...

Страница 13: ...o provide access to the amplifiers The DS10 in combination with the I O panel allows various configurations Two recommended configurations are detailed below Note For detailed information on how to co...

Страница 14: ...REMOTE section The REMOTE section allows the daisy chaining of rack assemblies within a remote network using the enclosed rack link cable Z5333 Rack Link For detailed specifications please refer to th...

Страница 15: ...ntrol via the d b Remote network CAN Bus is given in the technical information TI 312 d b code D5312 EN which can be downloaded from the d b website at www dbaudio com 5 3 Z5333 Rack Link The rack lin...

Страница 16: ...Mains power connection and internal mains supply distribution 6 Rack wiring diagrams d b Z5576 000 Manual 1 1 en 16...

Страница 17: ...Internal 4 CHANNEL OUTPUT wiring d b Z5576 000 Manual 1 1 en 17...

Страница 18: ...Internal audio INPUT and LINK wiring d b Z5576 000 Manual 1 1 en 18...

Страница 19: ...Internal Ethernet wiring and POE injection d b Z5576 000 Manual 1 1 en 19...

Страница 20: ...Internal CAN Bus wiring d b Z5576 000 Manual 1 1 en 20...

Страница 21: ......

Страница 22: ...D2029 EN 01 04 2018 d b audiotechnik GmbH www dbaudio com...

Отзывы: