2.3. Operation

NOTICE!

Only operate d&b loudspeakers with a correctly configured d&b

amplifier, otherwise there is a risk of damaging the loudspeaker

components.
Applicable d&b amplifiers:

D80/D20/D12/D6/10D/30D.

Application

Setup

Cabinets per

channel

Yi7P

Y7P

2

Yi10P

Y10P

2

For applicable amplifiers, the controller setups are available in

Dual Channel and Mix TOP/SUB mode.

2.3.1. Controller settings

For acoustic adjustment the functions CUT, HFA and CPL can be

selected.

CUT mode
Set to CUT, the low frequency level is reduced. The cabinets are

now configured for use with actively driven d&b subwoofers.

HFA mode
In HFA mode (High Frequency Attenuation), the HF response of the

system is rolled off. HFA provides a natural, balanced frequency

response when a cabinet is placed close to listeners in near field or

delay use.

High Frequency Attenuation begins gradually at 1 kHz, dropping

by approximately 3 dB at 10 kHz. This roll off mimics the decline

in frequency response experienced when listening to a system from

a distance in a typically reverberant room or auditorium.

CPL function
The CPL (Coupling) function compensates for coupling effects

between the cabinet and close boundary surfaces. CPL begins

gradually around 1 kHz, with the maximum attenuation below

400 Hz. To achieve a balanced frequency response, the CPL

function can be set to dB attenuation values between 0 and –9.

Positive CPL values create an adjustable low frequency boost (0 to

+5 dB) at around 65 Hz and can be set when the system is used in

full range mode without subwoofers.

-5

0

5

10

-10

-15

-20

-25

-30

20

100

1k

10k

20k

Frequency response correction in HFA mode

Frequency response correction of the CPL function

 

d&b Yi7P/Yi10P Manual 1.2 en

7

Содержание Yi10P

Страница 1: ...Y Yi7P Yi10P Manual 1 2 en ...

Страница 2: ...ence When reselling this product hand over this manual to the new owner If you supply d b products please draw the attention of your customers to this manual Enclose the relevant manuals with the systems If you require additional manuals for this purpose you can order them from d b d b audiotechnik GmbH Eugen Adolff Strasse 134 D 71522 Backnang Germany T 49 7191 9669 0 F 49 7191 95 00 00 docadmin ...

Страница 3: ...1 Product description 5 2 2 Connections 5 2 3 Operation 7 2 3 1 Controller settings 7 2 4 Dispersion characteristics 8 2 5 Technical specifications 10 3 Manufacturer s declarations 12 3 1 EU conformity of loudspeakers CE symbol 12 3 1 1 WEEE Declaration Disposal 12 Contents d b Yi7P Yi10P Manual 1 2 en 3 ...

Страница 4: ...es as detailed in our specific Mounting instructions or in our Flying system and Rigging manuals Ensure that all additional hardware fixings and fasteners used for installation or mobile deployment are of an appropriate size and load safety factor Pay attention to the manufacturers instructions and to the relevant safety guidelines Regularly check the loudspeaker housings and accessories for visib...

Страница 5: ...ch as the Z5398 YP Horizontal bracket the Z5399 YP Mounting bracket the Z5354 E8 E12 Flying adapter or the Z5020 25 Flying adapter 02 03 2 2 Connections The cabinets are fitted with a pair of NL4 M connectors and a two pole screw terminal block ST All four pins of both NL4 M connectors are wired in parallel The cabinets use the pin assignments 1 1 Pins 2 2 are designated to active subwoofers Cabin...

Страница 6: ... The two NL4 connector sockets of the cabinet s connector panel are located in a recess to allow the use of the cover plate 1 together with NL4 cable connectors as shown in the graphic opposite Note Neutrik NL4FC type connectors must be used for this option The cover plate is equipped with two knockout openings to allow daisy chaining of the loudspeaker To use the NL4 connection proceed in the sam...

Страница 7: ...cabinet is placed close to listeners in near field or delay use High Frequency Attenuation begins gradually at 1 kHz dropping by approximately 3 dB at 10 kHz This roll off mimics the decline in frequency response experienced when listening to a system from a distance in a typically reverberant room or auditorium CPL function The CPL Coupling function compensates for coupling effects between the ca...

Страница 8: ...persion characteristics Isobar diagram horizontal Yi7P vertical setup Isobar diagram vertical Isobar diagram horizontal Yi7P horizontal setup horn rotated Isobar diagram vertical d b Yi7P Yi10P Manual 1 2 en 8 ...

Страница 9: ... is visible through the front grill on each side of the cabinet as shown in the graphic opposite The HF horn can be rotated through 90 Tools required Torx wrench TX20 1 Undo the torx screws on the top and bottom panels of the cabinet and remove the front grill 2 Undo the screws holding the horn flange and rotate the horn 3 Refit the horn as follows Make sure the gasket of the horn is in place Refi...

Страница 10: ...l impedance 8 ohms Power handling capacity RMS peak 10 ms 400 1600 W Nominal dispersion angle horizontal Yi7P 75 Nominal dispersion angle horizontal Yi10P 110 Nominal dispersion angle vertical 40 Components 2 x 8 driver with neodymium magnet 1 4 exit compression driver Passive crossover network Connections 2 x NL4 M 1 x screw terminal ST up to 4 mm2 AWG 11 Optional fixed cable PG H07 RN F 2 x 2 5 ...

Страница 11: ...Yi7P Yi10P cabinet dimensions in mm inch d b Yi7P Yi10P Manual 1 2 en 11 ...

Страница 12: ...ons of the respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com 3 1 1 WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Please dispose of this product according to...

Страница 13: ......

Страница 14: ...D2711 EN 01 10 2016 d b audiotechnik GmbH www dbaudio com ...

Отзывы: