7. Care and maintenance / Disposal
7.1.
Transport / Storing
During transport ensure the rigging components are not stressed or
damaged by mechanical forces. Use suitable transport cases.
Due to their surface treatment the Q-Series rigging components are
temporary protected against moisture. However, ensure the components
are in a dry state while stored or during transport and use.
7.2.
Visual and functional inspection
[R1]
[R2]
[R3]
[R4]
[CR]
Fig. 34: Q1/7/10 rigging sockets
[R1]
Fig. 35: Q-SUB rigging sockets
Cabinet enclosure:
Visual inspection of all fitting plates including the Quick lock adapter
plate
[R3]
and front grills for obvious damage (e.g. cracks or
corrosion).
Inspection of all fitting plates including front grills to ensure they are
securely attached.
Using new pins perform a functional inspection of the Locking pin
sockets
[R1]
and for the Flying pin sockets
[R2/CR]
Inspection of the M10 threaded inserts
[R4]
.
Regularly lubricate the sockets and threaded inserts with WD-40
®
or a
similar product.
Z5153 Locking pins
Visual inspection regarding deformation and corrosion of the
component.
Inspection for missing ball bearings and damage.
Functional inspection of the ball bearings.
Functional inspection of the release mechanism to check it functions
properly.
Z5151 Q Splay and Z5152 Q Front links
Visual inspection regarding deformation and damage (e.g. cracks and
corrosion) including all holes of the component.
Z5159 Q Flying frame, Z5156 Q Flying adapter
Visual inspection regarding deformation and damage (e.g. cracks and
corrosion) including all holes of the component.
Z5155 Hoist connector chain / Z5048 Flying pin
Inspection according to the appropriate regulations for lifting devices.
7.3.
Disposal
When out of use the rigging components must be disposed in accordance
to the national environmental regulations.
Ensure that damaged rigging components are disposed in a way that they
can not be used again.
Q-Series Rigging manual
(1.2EN)