background image

Operation with D6 or D12

Select the controller setup E12-SUB.

Within the D12 amplifier this is available in "Dual Channel" and "Mix
TOP/SUB" mode.

Up to a total of two E12-SUBs can be driven by each D6 or D12
amplifier channel.

In applications with low continuous levels and low ambient temperatures
up to three cabinets can be connected to a D12 channel.

When the D12 is operated in "Mix TOP/SUB" mode, E12-SUB cabinets
and respective full range systems can be linked together locally and fed
by a single 4-wire cable from either amplifier output connector.

To apply SenseDrive for the subwoofer, EP5 connectors and 5-wire
cables have to be used. When operated in "Mix TOP/SUB" mode,
subwoofers have to be fed from the output B connector of the D12
amplifier.

Controller settings

For acoustic adjustment the 140 Hz function can be selected.

140 Hz circuit

If the 140 Hz setting is selected, the upper operating frequency of the
system is increased from 120 Hz to 140 Hz. This setting allows the E12-
SUB to operate with up to four E0 loudspeakers.

Operation with E-PAC

REMOTE
LO IMP

DELAY ON

CUT

HFA

SPKR

2

1

3 4 5 6

8

7

LO IMP

1

REMOTE

2

1

3 4 5

6

2 3 4

ON

ON

E-PAC version 1 

E-PAC version 2

Fig. 2: E-PAC configuration for E12-SUB

Selecting E12-SUB mode enables the E-PAC to drive one E12-SUB
loudspeaker.

For an E-PAC version 1 or 2, the configuration is selected by setting the
appropriate DIP switches on the rear panel. The E12-SUB configuration
on E-PAC version 2 is identical to the SUB configuration on E-PAC
version 1.

For an E-PAC version 3, the configuration is set via the encoder in
conjunction with an LCD.

The 140 Hz setting is available on version 3 (Firmware version 3.13 and
higher). The characteristics of the 140 Hz setting are explained in the
previous section "Operation with D6 or D12 - Controller settings".

E12-SUB Manual 

(4.1 EN)

Page 5 of 8

Содержание E12-SUB

Страница 1: ...E12 SUB Manual 4 1 EN ...

Страница 2: ...EN 03 2008 D2073 E 04 Copyright 2008 by d b audiotechnik GmbH all rights reserved Keep this manual with the product or in a safe place so that it is available for future reference When reselling this product hand over this manual to the new customer If you supply d b products please draw the attention of your customers to this manual Enclose the relevant manuals with the systems If you require add...

Страница 3: ... accessories as detailed in our specific Mounting instructions or in our Flying system and rigging manuals Ensure that all additional hardware fixings and fasteners used for installation or mobile deployment are of an appropriate size and load safety factor Pay attention to the manufacturers instructions and to the relevant safety guidelines Regularly check the loudspeaker housings and accessories...

Страница 4: ...igured d b amplifier otherwise there is a risk of damaging the loudspeaker components Connections 1 2 3 4 5 1 2 3 4 5 Sense Drive n c Fig 1 Wiring of the connectors The E12 SUB cabinet is fitted with a pair of EP5 connectors All pins of both connectors are wired in parallel The E12 SUB uses the pin assignments 3 4 and 5 Pin 5 SenseDrive D12 only and in conjunction with 5 wire cables Pins 1 2 are d...

Страница 5: ... selected 140 Hz circuit If the 140 Hz setting is selected the upper operating frequency of the system is increased from 120 Hz to 140 Hz This setting allows the E12 SUB to operate with up to four E0 loudspeakers Operation with E PAC REMOTE LO IMP DELAY ON CUT HFA SPKR 2 1 3 4 5 6 8 7 LO IMP 1 REMOTE 2 1 3 4 5 6 2 3 4 ON ON E PAC version 1 E PAC version 2 Fig 2 E PAC configuration for E12 SUB Sele...

Страница 6: ...essure 1 m free field with D6 125 dB SPLmax peak pink noise test signal with crest factor of 4 Input level 100 dB SPL 1 m 8 dBu E12 SUB subwoofer Nominal impedance 8 ohms Power handling capacity RMS peak 10 ms 200 800 W Connections 2 x EP5 Pin assignments 3 4 and 5 Pin 5 SenseDrive D12 optional 2 x NL4 Pin assignments 2 2 Weight 20 kg 44 lb Fig 4 E12 SUB cabinet dimensions in mm inch E12 SUB Manua...

Страница 7: ...he provisions of the respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Please dispose of this product accordin...

Страница 8: ...d b audiotechnik GmbH Eugen Adolff Str 134 D 71522 Backnang Germany Phone 49 7191 9669 0 Fax 49 7191 95 00 00 D2073 E 04 03 2008 d b audiotechnik GmbH ...