d&b audiotechnik D6 Скачать руководство пользователя страница 6

2. D6 Amplifier

Fig. 2: D6 Amplifier

2.1. 

D6 based systems

The D6 Amplifier incorporates:

- universal voltage, switch mode power supply with active power

factor correction (PFC)

- two channel Class D power amplifier

- digital signal processors (DSP) 

- comprehensive protection circuits

- controls and indicators

- analog and digital signal inputs and link outputs

- REMOTE and SERVICE interface

The level control on the front panel incorporates a digital rotary
encoder, which enables selection of all operating modes in conjunction
with a Liquid Crystal Display (LCD).

User definable equalization and delay functions are incorporated in
each channel of the D6. The 4-band parametric equalizer provides
optional Boost/Cut or Notch filtering and the signal delay capability
allows delay settings of up to 340 ms (= 100 m / 328 ft) to be applied
independently to either channel. A signal generator offering pink noise
or sine wave program is also incorporated for test and alignment
purposes. Each unit can be given a unique Device Name to simplify
identification and a password protected LOCK function is also
incorporated to inhibit unauthorized set up changes.

The D6 is housed in a 19" x 351 mm (13.8") 2 rack unit enclosure made
from steel.

2.2. 

Block diagram

Power

amplifier

Input

routing

Analog A
Analog B

Digital A
Digital B

Signal

generator

sine wave or

pink noise for
acoustic tests

Input

monitoring

1+/2+

1-/2-

User

EQ

Delay

t

Dynamics

Coil temp.

t

°

Power supply

Information

on headroom,

temperature,

power, mains

voltage

Excursion

Channel B

System

EQ/XO

pilot signals

for load

monitoring

Channel A

LC Display

Input
Ch A
Ch B
Link A>B

analog

> LINEAR
off

D6

remote

interface

uC

> LINEAR

1+/2+

1-/2-

Z analysis

for load

monitoring

I

D6 Amplifier, Hardware manual

(1.9 EN)    

Page 6 of 24

Содержание D6

Страница 1: ...D6 Amplifier Hardware manual 1 9 EN...

Страница 2: ...ace so that it is available for future reference When reselling this product hand over this manual to the new customer If you supply d b products please draw the attention of your customers to this ma...

Страница 3: ...10 3 2 2 ISP LED 10 3 2 3 GR LED 10 3 2 4 OVL LED 10 4 Connections 11 4 1 Mains connector 11 4 2 Signal inputs and link outputs 12 4 2 1 INPUT A B and LINK A B 12 4 2 2 INPUT DIGITAL AES EBU and LINK...

Страница 4: ...n areas and E4 outdoor use in rural areas Acoustic interference and malfunctions may occur if the unit is operated in the immediate vicinity of high frequency transmitters e g wireless microphones mob...

Страница 5: ...r if objects or liquids have entered the unit the unit is not operating normally the unit was dropped or the housing is damaged CAUTION Potential risk of explosion The unit incorporates a lithium batt...

Страница 6: ...s of up to 340 ms 100 m 328 ft to be applied independently to either channel A signal generator offering pink noise or sine wave program is also incorporated for test and alignment purposes Each unit...

Страница 7: ...orporated for cooling the internal components which allows greater cooling during louder program material The fan speed is consequently reduced during quieter passages preventing background noise inte...

Страница 8: ...D6 in Standby mode Note The setting of the MUTE A B switch is stored in the D6 when the mains power is turned off or disconnected After switching on or reconnecting the unit it will revert to its prev...

Страница 9: ...mping makes them susceptible to excitation by other loudspeakers in the surroundings Audible resonances may occur and even absorption of low frequency sound energy as the undamped loudspeakers act lik...

Страница 10: ...2 3 GR LED The GR LED 6 Gain Reduction illuminates yellow depending on the input signal The D6 limiter circuit reduces gain by more than 3 dB This state is not critical but indicates that the system h...

Страница 11: ...e the mains connector is accessible at any time to disconnect the unit in case of malfunction or danger Do not disconnect the PowerCon 1 mains connector from the unit while it is connected to the main...

Страница 12: ...Digital LINK Power fail Bypass Buffer Fig 5 Digital INPUT Bypass A 3 pin female XLR AES EBU 11 AES 3 input and a 3 pin male XLR LINK output 12 are provided The balanced input utilizes a transformer a...

Страница 13: ...ound AMP A OUT A INPUT A AMP B OUT B INPUT B Fig 6 NL4 Loudspeaker output connectors and channel assignment The D6 amplifier is supplied with NL4 output connectors 13 Pins 1 2 and 1 2 are wired in par...

Страница 14: ...bus signal active high 5 CAN_L CAN low bus signal active low 6 7 8 Enclosure GND CAN Ground The CAN Ground is routed via the cable shielding Within the CAN Bus network shielded cables and shielded RJ...

Страница 15: ...19 rack cabinet do not just rely on fixing and supporting amplifiers by their front panels Provide additional support using shelves fixed to the inner sides of the cabinet or rack or the mounting hol...

Страница 16: ...stribution can be downsized within the range given in the table The table gives power figures for various types of signal waveforms They were measured on a D6 driving a 4 ohm load both channels to the...

Страница 17: ...s per channel 400 watts total The thermal management of the D6 is designed to deliver this power for an unlimited amount of time within an ambient temperature of up to 40 C 104 F With higher ambient t...

Страница 18: ...nk noise or Sine wave 10 Hz to 20 kHz with 1 Hz detents Level 57 5 dB to 6 dB with 0 5 dB detents Buzzer Audible signal for error messages Monitoring according to IEC 60849 Sound Systems for Emergency...

Страница 19: ...d RMS analog input 105 dBr S N ratio unweighted RMS digital input 110 dBr Damping factor 20 Hz 1 kHz 4 ohms 90 Crosstalk 20 Hz 20 kHz 65 dBr Digital Signal Processing Sampling rate 96 kHz 27 Bit ADC 2...

Страница 20: ...re range 0 C to 45 C 32 F to 113 F reduced output power or short term operation Humidity rel average 80 Dimensions weight Height x width x depth 2 RU x 19 x 351 mm 2 RU x 19 x 13 8 Weight 8 kg 17 6 lb...

Страница 21: ...the provisions of the respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www...

Страница 22: ...D6 Amplifier Hardware manual 1 9 EN Page 22 of 24...