2.4. Technical specifications

B6-SUB system data

Frequency response (–5 dB standard)

37 Hz - 140 Hz

Frequency response (–5 dB 100 Hz mode)

37 Hz - 110 Hz

Max. sound pressure (1 m, free field) 
with D6/10D

128 dB

with D12/D20/30D

131 dB

with D80

134 dB

(SPLmax peak, pink noise test signal with crest factor of 4)

B6-SUB loudspeaker

Nominal impedance

8 ohms

Power handling capacity (RMS/peak 10 ms)

500/2000 W

Components

1 x 18" driver

Connections

2 x NLT4 F/M

optional 2 x NL4 M or EP5

Pin assignment

NLT4 F/M and NL4 M: 2+ / 2–

EP5: 3: + / 4: –

Weight

41 kg (90 lb)

B6-SUB cabinet dimensions in mm [inch]

B6-SUB frequency response, standard and 100 Hz mode

 

d&b B6-SUB Manual 1.1 en

7

Содержание B6-SUB

Страница 1: ...B B6 SUB Manual 1 1 en ...

Страница 2: ...ce When reselling this product hand over this manual to the new owner If you supply d b products please draw the attention of your customers to this manual Enclose the relevant manuals with the systems If you require additional manuals for this purpose you can order them from d b d b audiotechnik GmbH Eugen Adolff Strasse 134 D 71522 Backnang Germany T 49 7191 9669 0 F 49 7191 95 00 00 docadmin db...

Страница 3: ...UB loudspeaker 5 2 1 Product description 5 2 2 Connections 5 2 3 Operation 6 2 3 1 Controller settings 6 2 4 Technical specifications 7 3 Manufacturer s declarations 8 3 1 EU conformity of loudspeakers CE symbol 8 3 1 1 WEEE Declaration Disposal 8 Contents d b B6 SUB Manual 1 1 en 3 ...

Страница 4: ...ries as detailed in our specific Mounting instructions or in our Flying system and Rigging manuals Ensure that all additional hardware fixings and fasteners used for installation or mobile deployment are of an appropriate size and load safety factor Pay attention to the manufacturers instructions and to the relevant safety guidelines Regularly check the loudspeaker housings and accessories for vis...

Страница 5: ... wired in parallel The B6 SUB uses the pin assignments 2 2 Pins 1 1 are designated to TOP cabinets Using the male connector as the input the female connector allows for direct connection to a second cabinet The cabinet can be supplied with NL4 M or EP5 connectors as an option Pin equivalents of the connector options are listed in the table below NLT4 F M NL4 M 1 1 2 2 n a EP5 1 2 3 4 5 SenseDrive ...

Страница 6: ...ample in a distributed sound system The 100 Hz mode can also be used to compensate for the effect of close coupling between the B6 SUB and TOP cabinets operated in CUT mode CSA circuit The CSA Cardioid Subwoofer Array mode enables the combination of three or multiples of three subwoofer cabinets into an array which produces exceptional low frequency directivity control The amplifier channel for th...

Страница 7: ...ith D80 134 dB SPLmax peak pink noise test signal with crest factor of 4 B6 SUB loudspeaker Nominal impedance 8 ohms Power handling capacity RMS peak 10 ms 500 2000 W Components 1 x 18 driver Connections 2 x NLT4 F M optional 2 x NL4 M or EP5 Pin assignment NLT4 F M and NL4 M 2 2 EP5 3 4 Weight 41 kg 90 lb B6 SUB cabinet dimensions in mm inch B6 SUB frequency response standard and 100 Hz mode d b ...

Страница 8: ... respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com 3 1 1 WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Please dispose of this product according to the respe...

Страница 9: ......

Страница 10: ...D2716 EN 01 08 2014 d b audiotechnik GmbH www dbaudio com ...

Отзывы: