![d&b audiotechnik 40D Скачать руководство пользователя страница 36](http://html2.mh-extra.com/html/dandb-audiotechnik/40d/40d_reference-manual_4354267036.webp)
Service/Maintenance and care
9.3 Possible error messages
The following table lists possible error messages appearing within
the Web Remote interface ordered by the error Id.
ID
Display text
Eventlog text
Description
Location
Possible reasons
11
System error 128
System error 128
(I2C, IC 0x%02X,
Pos %d)
Internal I2C comm.
error
DS
Internal hardware or
software fault
15
Unknown device type Unknown device type
%d
Unknown device type
Wrong or missing
serial No.
16
Invalid device ident
Invalid device ident
%d
Invalid hardware
configuration
ADDAC, Amp, SMPS Missing or wrong
module identification
19
Invalid display ident
Invalid display board
ident %d
Invalid DISPLAY
identification
Display
Missing or wrong
DISPLAY identification
20
Program error %u
Program error %d,
%d, %d, %d
Program error
DSP
Various
21
Invalid DSP Data
Invalid DSP database
(Position %d, Error
%d)
Invalid DSP data
DSP
Software error
25
Program error %u
Program error %d:
AWL error %d in
AWL %d, line %d
Program error
DSP
Various
27
SMPS in bootloader
SMPS stuck in
bootloader
Software missing on
SMPS controller
SMPS
Firmware update
failed or flash
corruption, retry
update
28
SMPS comm. error
SMPS communication
error (error %04X)
SMPS comm. error
Missing keepalive for
1 sec
SMPS
SMPS fault or internal
communication
disturbed
30
SMPS temp. error %d
°C
SMPS temperature
error %3d°C (power
%uW)
Critical SMPS
temperature
SMPS
Insufficient cooling
32-34
SMPS supply error
SMPS supply error
XXXVXXX (%5dmV,
err %04X)
Supply voltage out of
range
SMPS
Fluctuating mains
voltage, SMPS fault
35
SMPS ZK1
overvoltage
SMPS supply error
Zk1 overvoltage
(Zk1 %3dV, %04X)
Supply voltage out of
range
SMPS
36
Mains surge
Mains surge detected
(Zk1 peak %3dV,
Mains peak %3dV)
SMPS surge restart
SMPS
Rapid surge on mains
voltage
37
Mains undefined
range
Mains undefined
range (avg %3dV, err
%04X)
Mains voltage out of
range at startup
SMPS
Refer to:
38
SMPS overcurrent
SMPS overcurrent (i-
peak %3.1dA, avg
%3dV, err %04X)
SMPS overcurrent
SMPS
Refer to:
39
Mains overvoltage
Mains overvoltage
(avg %3dV, peak
%3dV, err %04X)
Mains voltage too
high for current range
SMPS
Refer to: