background image

17

16

Manual

Manual

STAGE 5

End section installation 

In the variant of 
installation of the 
greenhouse without a 
foundation, marking 
of axes is made on the 
ground in accordance 
with

 fig. 5.1

 and holes 

70 cm deep are dug for 
foundation stay braces 
with supports.
 In the variant of 
installation of the 
greenhouse on a 
foundation in accordance 
with f

ig. 5.1

, cleater 

angles are mounted to 
the foundation for the 
subsequent fastening on 
them bottom ends of arcs 
in accordance with fig. 
5.2 without foundation 
stay braces.

 The end section is lifted 
and placed in a vertical 
position on the prepared 
place.

200*

2042

2132

L=4084+2132хN*

2132

2042

fig. 5.1

Fig. 5.2

5000

200*

84

100

200*

200*

45

42

100

*N -number of sections of the gr

eenhouse, excluding end sections, r

ef. p.2 

STAGE 6

Extension of the frame 
length.

Fig. 6

4

5

Assembled power arc (or 
other end wall, depending 
on the needed length 
of the greenhouse) is 
brought to the assembled 
end section at the 
distance of the main 
runner and joined to 
it with the use of main 
runners 

2 and 2н

 align 

the side flanges of shapes 

(fig. 6).

 It is recommended to 
connect the outermost 
and middle runners first, 
using a stepladder.
 

Next power arc is joined 
to the power arc that has 
already been connected, 
and so on all the arcs are 
alternatively joined

INSTALLATION SEQUENCE

INSTALLATION SEQUENCE

Содержание TITAN Peak 240 5,0

Страница 1: ...for Greenhouse TITAN Peak 240 5 0 Manual 17 02 2020...

Страница 2: ...any length multiple of 2 1 min 4 2 m width 5 0 m height 3 6 m...

Страница 3: ...GE TITAN Peak 240 90 75 2800 10 5 3 PACKAGE TITAN Peak 240 90 120 1990 32 36 4 PACKAGE TITAN Peak 240 90 65 2360 11 12 5 PACKAGE TITAN Peak 240 90 70 2720 17 10 6 PACKAGE TITAN Peak 240 90 55 1145 2 6...

Страница 4: ...26 End seal 1 19 9 PACKAGE TITAN Peak 240 Outermost ridge 2 2 1 able 3 DETAILED PARTS LIST INSERT marking name quantity pcs length m 1 PACKAGE INSERT 20 Ridge arc 2 1 76 4 Arc 2 3 1 2 PACKAGE INSERT...

Страница 5: ...tom arc base sheet 2 2 91 Outermost base sheet for a runner 2 2 04 Tingle 20 0 09 Main shape 2 2 10 Washer 32 6 12 Bolt 6 14 34 Bolt 6 20 12 Bolt 6 60 2 Nut 6 48 Washer 6 50 Double size scotch tape 1...

Страница 6: ...ding outside of the greenhouse in front the door d e l b m e s s a s i e s u o h n e e r g e h T s e r u g i f n i n w o h s d n a d e r e t t e l e r a s t i n u y l b m e s s A by means of bolts of...

Страница 7: ...1 1 5 5 5 4 3 9 10 4 4 4 2 2 2 2 2 2 26 26 11 ONE INSERT extends the greenhouse by 2 13 m Number of the inserts for the greenhouse is not limited Fig 1 GENERAL VIEW OF THE GREENHOUSE FRAME WITH EXTEN...

Страница 8: ...al view of the end wall angle 11 10 9 sunken screw 6 10 Determine the places of installation of angles in accordance with fig 1 8 and install the angles together with the strip 11 10 9 Strips with the...

Страница 9: ...st side walls of shapes of arcs 4 until the next operation bolt angle fig 4 2 Installation of longitudinal stiffness side braces STAGE 4 Fig 4 1 2 STAGE 3 Assembly of the power arc Assembly of the pow...

Страница 10: ...tical position on the prepared place 200 2042 2132 L 4084 2132 N 2132 2042 fig 5 1 Fig 5 2 5000 200 84 100 200 200 45 42 100 N number of sections of the greenhouse excluding end sections ref p 2 2 STA...

Страница 11: ...embly The gate is assembled in the same way Joints are shown in the figures Strips and other surface mounted components are installed after the main shape parts are assembled STAGE 7 13 12 14 12 13 sc...

Страница 12: ...0 cutting line 1490 1490 Install honeycomb polycarbonate with a specified side facing outwards sunward this side has a covering layer make sure to clarify it on buying or prior to installation Coverin...

Страница 13: ...the end to the angles with the use of washers and self tapping screws fig 8 2 Places of fastening of pieces of covering to each other with the use of a permanent polycarbonate connecting shape are sho...

Страница 14: ...gles on arcs 2430 2430 2 1 0 0 nut 6 Ridge shape bolt 6 20 big arc base shee small arc base sheet washer 32 6 Do not tighten up 2 3 5 0 double size scotch bolt 6 14 outermost base sheet for a runner o...

Страница 15: ...raw band nut 6 washer 6 bolt 6 60 washer 6 bend the ends of the tingle after tightening of the draw band Top draw band bottom draw band ase sheet for a runner main shape bolt 6 14 Top draw band tingle...

Страница 16: ...0 germany dancover com Switzerland 0840 000125 schweiz dancover com France 0975 181 800 france dancover com Austria 0662 626935 austria dancover com Sweden 040 233 262 sverige dancover com Finland 0 9...

Отзывы: