Страница 1: ...12 04 2019 for Greenhouse TITAN Classic 480 Manual ...

Страница 2: ...mm diameter hexagon wrench or an open end wrench A Phillips screwdriver or a battery powered screwdriver A shovel to dig holes A level to measure flatness of a pad Ropes to measure a diagonal Knife to cut polycarbonate sheets Follow local building regulations if necessary If a strong wind or a storm occurs close windows or doors Before starting to assembly the greenhouse you must read all instruct...

Страница 3: ...ouse 2065 2 15 Sides of the foundation for greenhouse extension 2065 2 16 Front and back parts of the foundation 2350 2 2 17 Foundation angles 4 4 18 Foundation connection plates 4 19 Polycarbonate connection angles large angle 14 14 20 Polycarbonate and bar connection angles small angle 8 8 21 Polycarbonate connection plates with 2 holes 5 5 22 Ridge for 2 12 m length greenhouse 2120 1 23 Ridge f...

Страница 4: ...rts for walls 1050x1485 4 6 Polycarbonate parts for walls 985x1485 4 Side parts for the front and the end 700x1950 4 4 Bottom part of the door 960x1230 1 1 Upper part of the door 960x650 2 2 Triangle above the door 920x400 2 2 Polycarbonate part below the window 1020x1230 1 1 ATTENTION Before installation of the greenhouse it is necessary to read all assembly instruction In order to prevent accide...

Страница 5: ...s extension Foundation connection plates 18 are used for extension of the foundation if TITAN Classic 480 greenhouse length exceeds 2 12 m or 3 17 m They are fixed from both sides with M5 12 bolts 27 M5 nuts 30 Fig 1 6 If length of the greenhouse is 4 12 m the foundation is connected as follows 2 12 m 14 2 m extension of the side of the foundation 15 If length of the greenhouse is 5 17 m the found...

Страница 6: ...epth around the whole perimeter of the foundation near fixing points made in the foundation in order to dig in side lower bars No 1 Fig 3 2 12 m 5 holes on the sides 3 17 m 7 holes on the sides 4 12 m 9 holes on the sides 5 17 m 11 holes and etc Fig 3 4 Tighten the polycarbonate connection plates 21 to the front and back parts of the foundation 16 with M5 12 bolts 27 and M5 nuts 30 Fig 4 1 4 2 ...

Страница 7: ...ig 5 Fig 5 6 Tighten the prepared side lower bars No 1 to the side parts of the assembled foundation with M5 12 bolts 27 and M5 nuts 30 Fig 6 1 6 3 Fig 6 1 Fig 6 2 Fig 6 3 7 Side lower bars No 1 are fixed by tightening the bar fixing cross bars depending on the length of the greenhouse No 5 No 6 or No 7 with M5 12 bolts 27 and M5 nuts 30 Fig 10 The same action is to be carried out on both sides Fi...

Страница 8: ...If greenhouse length is 6 12 m cross fastening of the bars is connected as follows 2 12 m No 6 2 07 m No 7 2 07 m No 7 If greenhouse length is 7 17 m cross fastening of the bars is connected as follows 3 17 m No 5 2 07 m No 7 2 07 m No 7 Fig 7 3 Fig 7 4 8 Separately connect the upper bars No 2 to the connectors of the upper bar a plate with 4 holes 12 with M5 12 bolts 27 and M5 nuts 30 then tighte...

Страница 9: ...wer bars No 1 with M5 12 bolts 27 and M5 nuts 30 with the bar connection plates 12 Fig 9 1 9 3 Fig 9 1 Fig 9 2 Fig 9 3 10 Fix the side No 1 and the upper bars No 2 to each other by fixing profiles for sides and a ridge No 3 with M5 20 bolts 28 and M5 nuts 30 The same action is to be carried out with all bars Fig 10 1 10 2 ...

Страница 10: ...h M5 12 bolts 27 and M5 nuts 30 Fig 11 1 11 3 Fig 11 1 Fig 11 2 Fig 11 3 12 Tighten the polycarbonate connection angles 19 and the bar connection angles 20 to the side lower bars No 1 the upper bars No 2 and the side bar cross bars No 4 No 5 or No 6 with M5 12 bolts 27 and M5 nuts 30 Fig 12 1 12 2 Fig 12 1 ...

Страница 11: ... No 7 with M5 12 bolts 27 and M5 nuts 30 This action is carried out analogically in the front and at the back Fig 13 1 13 3 Fig 13 1 Fig 13 2 Fig 13 3 14 Tighten the door and back bars No 8 to the door and back bar holders No 9 The upper part of the bar is to be fixed to the door and back bar holders No 9 and the lower part is to be fixed to the front part of the ...

Страница 12: ...3 Fig 14 4 15 In the front and at the back of the greenhouse tighten the door and back fixtures No 10 to the door and back bars No 8 with M5 12 bolts 27 and M5 nuts 30 Additionally at the back of the greenhouse between the door and back bars No 8 tighten the rear part fixture No 11 Fig 15 1 15 7 Fig 15 1 Fig 15 2 Fig 15 3 Fig 15 4 Fig 15 5 Fig 15 6 Fig 15 7 ...

Страница 13: ...saw with small teeth a sharp knife if necessary Before installation it is necessary to remove films SAFETY GLOVES ARE NECESSARY TO WEAR WHEN CUTTING SHEETS 17 Upon tightening the frame part of the greenhouse installation of polycarbonate is to be started Start fixing polycarbonate sheets from the rear part of the greenhouse Apply the part of back wall polycarbonate sheet below window 1020x1230 mm ...

Страница 14: ... The polycarbonate sheet is tightened to the bar connection angles 19 20 and the polycarbonate connection plates 21 with M5 20 bolts 28 M5 nuts 30 and gaskets 31 The sheet is tightened to the bars of the rear part of the greenhouse No 8 and the bar fixtures No 9 No 10 and No 11 with M5 40 bolts 29 M5 nuts 30 and gaskets 31 Then cut polycarbonate near the frame profile with a sharp knife or a jigsa...

Страница 15: ... 31 and to bar connection angles with M5 20 bolts 28 M5 nuts 30 and gaskets 31 Then cut polycarbonate near the frame profile with a sharp knife or a jigsaw if necessary Fig 19 1 19 2 Fig 19 1 Fig 19 2 20 Apply sealing rubber 36 on the top of channels of side polycarbonate sheets at the top and on the sides of the front and the rear parts of the greenhouse and only after that put side and upper par...

Страница 16: ...ts are used to cover the walls Sheet arrangement side view for walls and roof 2 12 m length 1 05 1 05 m Fig 21 1 3 17 m length 1 05 1 05 1 05 Fig 21 2 4 12 m length 1 05 0 985 0 985 1 05 m Fig 21 3 5 17 m length 1 05 1 05 0 985 0 985 1 05 m Fig 21 4 6 12 m length 1 05 0 985 0 985 0 985 0 985 1 05 m Fig 21 5 and etc ...

Страница 17: ......

Страница 18: ...5th 7th and 9th bars and etc ATTENTION Remove the protective film from the connecting profiles if any Fig 21 6 Fig 21 7 To cover the walls of 4 12 m length TITAN Classic 480 greenhouse 2 sheets of 1050x1485 mm and 2 sheets of 985x1485 mm are needed The sheets are inserted into the connecting H profiles downward from the top Polycarbonate edges at the front and at the back must overhang up to the e...

Страница 19: ...than 2 12 m the H profiles are to be tightened to the bars as follows starting from the front of the greenhouse 3 17 m 3rd and 5th bars 4 12 m 3rd 5th and 7th bars 5 17 m 3rd 5th 7th and 9th bars and etc ATTENTION Remove the protective film from the connecting profiles if any Fig 22 1 For instance to cover the roof of 4 12 m length TITAN Classic 480 greenhouse 2 sheets of 1050x1485 mm and 985x1485...

Страница 20: ... ridge 22 23 Ending F profiles which are fixed by F profile holders 38 are put onto the lower ends of the sheets 39 40 and 41 Fig 22 4 22 7 The holders are tightened to the frame with M5 40 bolts 29 M5 nuts 30 and gaskets 31 Fig 22 4 Fig 22 5 Fig 22 6 Fig 22 7 ...

Страница 21: ...Fig 23 1 Fig 23 2 Fig 23 4 24 Assembly of the lower and the upper parts of the door Connect all parts supplied in the set of the lower part of the door DOOR No 5 DOOR No 6 DOOR No 3 into a rectangle with M5 12 bolts 27 and M5 nuts 30 Tighten vertical parts of the door to the assembled frame DOOR No 7 Fig 24 1 Fig 24 1 Connect all parts supplied in the set of the upper part of the door DOOR No 1 DO...

Страница 22: ...ower 960x1230mm and upper 960x650mm part of the door to the fixed frame parts of the door with M5 40 bolts 29 M5 nuts 30 and gaskets 31 Fig 24 4 NOTE polycarbonate covering of the upper door overhangs the lower door Upper polycarbonate channels of the door depending on configuration are to be sealed by the plate protection strip or the ending aluminium U profile 42 Attach the handle 25 to the prep...

Страница 23: ...e in tended for that on the same level with the upper door window handle Make a loop from the door opening holder supplied to you 35 Eyelets of all opening closing doors are made at the handle level with M5 nuts 30 and gaskets 31 Fig 25 1 25 2 Fig 25 1 Fig 25 2 ...

Страница 24: ...40 germany dancover com Switzerland 0840 000125 schweiz dancover com France 0975 181 800 france dancover com Austria 0662 626935 austria dancover com Sweden 040 233 262 sverige dancover com Finland 0 931 581 720 suomi dancover com Nederland 0 858 880 524 nederland dancover com Poland 22 300 8602 polska dancover com Ireland 0 151 33 003 ireland dancover com Luxembourg 49 041 0266 7040 luxembourg da...