LEAK TEST
Gas connections on the appliance are leak tested at the factory prior to shipment. Possible
mishandling of the appliance during the shipment might contribute to product integrity as a whole.
A complete gas leakage test must be performed again at the installation site. Please follow the
procedure below for leakage test.
-
Make a soap solution of one part liquid detergent and one part water. The soap solution can be
applied with spray bottle, brush or rag. Soap bubbles will appear where a leak is present.
-
Make sure the control tap is in the OFF position (full disk =
●
) on the control panel.
-
Turn on the gas supply and check for bubbles from the hoses and connections. Presents of
bubble means that a leak path is present.
-
If a leak is present, turn OFF the gas supply immediately, tighten any leaking fitting carefully,
turn gas again and recheck.
-
Never leak test while smoking.