DUCTING
Determine whether the hood will discharge vertically or
horizontally. For vertical or horizontal discharge, run ductwork
between the hood location and roof cap or wall cap.
A minimum 6” round duct must be used to maintain maximum
airfl ow effi ciency.
Always use rigid type metal ducts only.
Whenever possible, reduce the number of transitions and turns
in the ducting. If a long duct length is required, increase the
duct size from 6” to 7”.
If elbows or bends are required; install them as far away from
the hood as possible.
Minimum mounting height between the range and the bottom
of the hood should be no less than 26”.
Maximum mounting height between the range and the bottom
of the hood should be no more than 34”.
WARNING!
FIRE HAZARD
1. NEVER implement ducting in a space between walls, crawl
spaces, attics or garages. All exhaust must be vented outside.
Use metal ducting only. Fasten all connections with sheet
metal screws and certifi ed silver tape or duct tape.
2. See Fig. 1 below for placement of ducting and electrical
cutout in wall. For a non-ducted installation, DO NOT cut a duct
access hole.
PREPARE THE HOOD
Unpack hood and check contents.
You should receive:
1 - Hood
2 - (A) Decorative Flue Assembly
1 - Parts Bag containing:
2 - (B) Flue Mounting Bracket
2 - (C) Mounting Screws (M3 x 8mm Pan Head)
2 - (D) Mounting Screws (M4 x 8mm Round Head)
2 - (E) Mounting Screws (ST4 x 12mm Self Tapping)
2 - (F) Mounting Screws (ST4 x 35mm Self Tapping)
4 - Drywall Anchors [(G) 6 x 30mm & (H) 8 x 35mm]
1 - Installation Instructions
ROOF CAP
DECORATIVE
FLUE
6" ADAPTER
WALL CAP
26"~34"ABOVE
COOKING
SURFACE
ROUND
DUCT
HOOD
ROUND ELBOW
A
B
C
D
E
F
G
H
FIG. 1