TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
No power
• A fuse may be blown or the circuit breaker
tripped
• Plug not fully inserted into the wall outlet
Internal temperature not cold enough
Appliance runs continuously
• Door is not shut properly or opened excessively
• Exhaust vent is obstructed
• Recently added a large quantity of warm bottles
to the cabinet
• Close proximity to heat source or direct sunlight
• Ambient temperature or humidity is very high
• Possible system leak, evaporator fan failure or
compressor failure
Condensation on the cabinet or door
• Door is not shut properly or opened excessively
• Ambient temperature or humidity is very high
Danby Consumer Care: 1-800-263-2629 or [email protected]
Hours of operation:
Monday to Thursday 8:30 am - 6:00 pm Eastern Standard Time
Friday 8:30 am - 4:00 pm Eastern Standard Time
Information in this manual is subject to change without notice.
ERROR CODES
C0
• control system communication fault
E1
• interior sensor fault
E2
• defrost sensor fault
dr
• door is open for more than 1 minute
EH
• internal temperature is 8 degrees higher than the set temperature for more than 30 minutes
EL
• internal temperature is 8 degrees lower than the set temperature for more than 30 minutes
If error codes appear on the display for more than 5 minutes, a power reset may rectify the issue. Unplug
the appliance, wait 5 minutes and then plug the appliance back in. If the error code persists after a power
reset, contact consumer care or an authorized service agent.
8