Dugan Model E User Guide
ASCII Remote Control
42
Headroom
Returns the current headroom state. HR 0 = -10 dBU and HR 1 = +4 dBU.
Master or Slave Mode
Queries the master/slave mode of the unit (0 = Slave, 1 = Master).
Version
This command returns the microcontroller and DSP firmware versions.
Example
Meaning
Sent
HR
What is the headroom state?
Reply
HR 1
Headroom = +4 dBU
Example
Meaning
Sent
MM
What is the master/slave mode of the Model E?
Reply
MM 1
Model E = Master mode
Example
Meaning
Sent
VE
What are the firmware versions?
Reply
VE 1.0, 1.0
microcontroller = 1.0, DSP = 1.0