background image

4

WARNING

• All units must be equipped with a 3-wire service. Connect the ground wire according  
   to the instructions.

• This product must be installed only by qualified persons. Use 2.0mm

2

 (AWG) NO.14 wiring.

• Turn off the power to the unit before servicing or cleaning. All wires must be disconnected.
• Incorrect installation, defect power cords, or failure to properly ground unit could result in  
   electrical shock or life-threatening injuries.

NOTE

 

We 

do not recommend to install this product less than 300 mm above washbasin, tabletop or 

other surface. This product is suitable for indoor use only.

Type Y connection: If the power supply cord is damaged, it must be replaced immediately. 

Only qualified persons shall be permitted to replace the cord to avoid a hazard. Disconnect the 

electricity supply cord according to instructions.

This product is not intended for use by persons (inclusive children) with reduced physical, 

sensory or mental capabilities, or lack of experience and knowledge, unless they are 

supervised or have been given instruction concerning use of the product by a person 

responsible for their safety.

Children should be supervised to ensure this product is used correctly.

GENERAL SAFETY INFORMATION

CIRCUIT DIAGRAM

!

Содержание Loki

Страница 1: ...USER MANUAL LOKI HAND DRYER Model 4000 4007...

Страница 2: ...the manufacturer retailer for proper treatment recovery and recycling Dimensions and technical specifications 3 General safety information 4 Circuit diagram 4 Installation 5 User guide 6 Recommended i...

Страница 3: ...ostate turns circuit off at 85 C thermal fuse turns off at 142 C Drying time 10 15 seconds Stand by power 0 3 0 4W Sensor type Infrared self adjusting Sensor range 110 230 mm adjustable Standard 170mm...

Страница 4: ...asin tabletop or other surface This product is suitable for indoor use only Type Y connection If the power supply cord is damaged it must be replaced immediately Only qualified persons shall be permit...

Страница 5: ...ten with the retaining clip NOTE Colours of live and neutral wires depend on voltage of supply service 5 Connect supply wires to terminal block Connections A Connect live wire coloured red brown or wh...

Страница 6: ...ch operation Shake excess water from hands Place hands under the outlet to start operation Rub hands lightly and rapidly Stops automatically after hands are removed CLEANING AND MAINTENANCE Disconnect...

Страница 7: ...ement switch is located on the timer Adjust with a flat screwdriver Slide switch to ON heating element on Slide switch to 1 heating element off SENSOR RANGE ADJUSTMENT The sensor range is adjustable b...

Страница 8: ...USED HAND DRYERS The dryer does not run First ensure that the breaker supplying the dryer is opera tional If it is disconnect the power and remove the cover Replace PCB and IR sensor Taking suitable p...

Страница 9: ...outlet bracket 10 Circuit Print Board 11 Cable protector 12 Bracket for IR sensor 13 IR sensor 14 Terminal block 15 Insulation mylar shield with LNG mark 16 Cable clamp 17 Base plate 18 Grounding scr...

Страница 10: ...10 DAN DRYER A S Alsikevej 8 DK 8920 Randers NV T 45 8641 5711 E info dandryer dk W dandryer com...