-12-

WarnInG: 

DO NOT attempt to rectify errors using unqualified personnel. 

To remedy the following errors, a qualified professional is required.

noTe: 

With any error code, it is suggested to turn the unit off, wait five 

minutes, and then turn the unit on again. If the error code is still present, a 

qualified professional is required to fix the problem.

CoDe meanInG

DIsplay 

reaDInG

soluTIon*

E1

Coil sensor 

error

Flashes every 

30 seconds

Replace coil sensor. Call for 

replacement part.

E2

Humidity 

sensor error

Flashes every 

30 seconds

Replace humidity sensor. Call 

for replacement part.

E3

Low or no 

refrigerant

Flashes 

continually

Turn the unit off, wait 5 

minutes, and power the unit 

ON. If E3 shows again within 

15 mins after turning the unit 

back on, then we can confirm 

the unit refrigerant leak 

requires professional repair. 

Call your local HVAC repair 

shop for assistance.

E4

Water pump 

fault or 

blockage

Flashes 

continually

Dehumidifier will turn OFF 

automatically. Check for 

blockages in the water hose. If 

there are no visible blockages, 

the pump or water pipe may 

need to be replaced. 

error CoDes

*NOTE: If the error occurs within one year from the date of purchase, 

contact Consumer Services at 877-365-6274 for warranty assistance 

prior to contacting a repair person. You must have the original 

purchase receipt for warranty assistance.

Содержание PACD200

Страница 1: ...ing your commercial dehumidifier please read this manual carefully and keep it for future reference along with your receipt Your Source for Home Comfort FOR MODEL PACD200 COMMERCIAL DEHUMIDIFIER USER MANUAL DEHUMIDIFIER ...

Страница 2: ......

Страница 3: ...e intact and complete In the unlikely event of missing parts contact Consumer Services at 877 365 6274 DO NOT leave children unattended with any of the packaging as it is a potential source of danger Disposal of all packaging must be carried out responsibly safely and in accordance with your local regulations ALWAYS recycle the packaging material where possible When using any electrically powered ...

Страница 4: ...to moisture of any kind 7 Turn off and unplug from the power socket when not in use before assembling or before cleaning 8 The dehumidifier is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with the dehumidifier 9 Disabled persons and the elderly may require assistance with set up and usage 10 Do not place objects on t...

Страница 5: ...DO NOT OBSTRUCT THE AIR INLET OR OUTLET WARNING NOTE You will need to install the handle Six bolts are included for the installation Structure Diagram r securing the handle 6 Bolts for securing the handle ...

Страница 6: ... UP THE DEHUMIDIFIER Operate the dehumidifier in an enclosed area as this creates a drying chamber Close all doors windows and areas that open to external areas to maximize the dehumidifier s water removal efficiency Keep traffic through the drying chamber to a minimum Place the dehumidifier in the center of the room away from walls and furnishings DO NOT allow the airflow to be obstructed Illustr...

Страница 7: ...ge above DRAINAGE The dehumidifier pump connects to a plastic drainage hose The hose is stored on the back of the appliance Uncoil the entire hose ensuring there are no kinks or restrictions and place the unattached end into a drain or run outdoors Ensure that draining running to the outdoors does not create a hazard that could cause someone to slip Water drains MUST be checked regularly when used...

Страница 8: ...d Press and keys to set or adjust humidity in the range of 26 and 90 When the environmental humidity is below 26 CO will be displayed Defrost Indicator The unit begins to defrost when the defrost indicator illuminates the unit has stopped defrosting when the light is no longer illuminated When defrosting is complete the unit begins to dehumidify again automatically 1 ON OFF Key 2 UP and DOWN Keys ...

Страница 9: ...urs from the previous time the unit ran will display for 10 seconds Within the 10 seconds if T is pressed again the total working time will display for 10 seconds If there is no action within those 10 seconds the LED will automatically shut off If T is pressed when LED displays the total working time the LED will shut off immediately The current working time will be deleted by pressing and holding...

Страница 10: ...ll of the keys on the control panel will lock The control panel can then be unlocked by pressing the T and P keys together again for 2 seconds Vent Hose Function To speed up drying in very damp place use a plastic pipe vent hose with a diameter larger than 6 7 inches Attach the vent hose to the exhaust ring see below to expedite drying by directing the heat exhaust toward the wet area Operating In...

Страница 11: ... be greatly reduced if the filter becomes blocked 1 Remove the filter as shown in the diagram below 2 Vacuum any debris from the filter using the vacuum hose and nozzle attachment 3 Using lukewarm water and a mild detergent wash the filter and allow to dry completely 4 Once completely dry re install the filter into the dehumidifier Maintenance Pull filter out from the left side Air filter ...

Страница 12: ... with a new battery 4 Refit the control panel onto the PCB 5 Replace the four screws Maintenance continued Check the electrical cord for damage before each use Additionally it is a good practice to check the drain hose on a monthly basis for any obstructions Disconnect and clear any debris present then reconnect the hose When cleaning the surface of the unit do not use any harsh or abrasive cleane...

Страница 13: ...k drainage flow Dehumidifier collects little no water Insufficient working time Allow more working time Filter is blocked Clean filter Low ambient temperature Increase ambient temperature Condensate hose is blocked Check hose for restrictions Difference between set humidity and current actual humidity is minimal Adjust humidity setting to a lesser setting Humidity is too low for the unit to run No...

Страница 14: ...lacement part E3 Low or no refrigerant Flashes continually Turn the unit off wait 5 minutes and power the unit ON If E3 shows again within 15 mins after turning the unit back on then we can confirm the unit refrigerant leak requires professional repair Call your local HVAC repair shop for assistance E4 Water pump fault or blockage Flashes continually Dehumidifier will turn OFF automatically Check ...

Страница 15: ... 13 PURCHASE RECORD MAINTENANCE RECORD Purchase Date Serial Number Distributor Tel DATE SERVICE PERFORMED PERFORMED BY ...

Страница 16: ...tributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in China 877 365 6274 www perfectaire us DEHUMIDIFIER ...

Отзывы: