Serie "LXS9"
Pagina A - 7
Rev. M - 01
D)
This message appears on the display:
If the product drop sensors (FTCA)
are installed
on the vending machine,
XXX = ON
If the product drop sensors (FTCA)
are not installed
on the vending machine,
XXX = OFF
press
F
to confirm
E)
After a short time, the sliding panel will perform a cycle of opening and closing,
if appears “OFF L13b
SD Motor Disconnected”, it is necessary to turn on the door open switch and press any button to check
the open/close cycle.
Once the open/close cycle is complete, if any other problem is not found, you can pass directly to the “F”
point , if wrong opening and closing times of the sliding panel values are found, there will appear the
following message on the display:
Press 1 key to perform the automatic calibration of time/speed of opening/closing of the sliding panel. At
the end of the test the following message appears on the display:
press
F
to confirm
F)
The following message will appear shortly on the display:
Possible values:
0
,
1
,
2
:
If the value is „
0
‟ (zero), there is no refrigerator probe connected; the following message will appear when
F
is pressed:
With “OFF” mode, refrigerator operation is deactivated; the self-learning procedure ends when the
F
key
is pressed and the vending machine returns to the programming menu. No other modes can be selected.
If the value is „
1
‟ (One), there is just one refrigerator probe connected; the following message will appear
when the
F
key is pressed:
It is possible to confirm
“Drink & Snack” mode or, alternatively, select the “OFF” mode.
In “Drink & Snack” mode, refrigerator operation is activated without management of the safety temperature
of the food zone; the self-learning procedure ends when the
F
key is pressed and the vending machine
returns to the programming menu.
If the
value is „
2
‟ (Two), there are two refrigerator probes connected; the following message will appear
when the
F
key is pressed:
or,
It is possible to confirm “FOOD & Snack” mode or, alternatively, select the “Drink & Snack” mode or “OFF”.
Management of the safety temperature is activated when “FOOD & Snack” mode is selected; the following
message will appear when the
F
key is pressed:
The safety temperature value is displayed with the possibility of changing it; press
F
to confirm.
If an incorrect message appeared on the display during phase
F)
, carry out the operations described in the
“
Installation and service
” manual, referring to the “
OFF
L01
and
OFF
L02
”
messages.
Self-learning
FTCA sensors:XXX
Self-learning
Conn. probes x
Security Temper.
*> 7.0°C
Refrig.operation
OFF
Refrig.operation
Drink & Snack
Refrig.operation
Drink & Snack
Refrig.operation
FOOD & Snack
Pannel. Scorrev.