5
Parameter description
5.1 GMS/BRM-DM1/2
BRM GMS System
GMS measure system: 1:GMS-V1T01, 2:GMS-V1A01, 3:GMS-V1A02, 4:GMS-
V2A01, 5:GMS-V2T01, 6:GMS-V1X01, 7:GMS-V1X02.
BRM Can Node no.
Node number, normal 1, use 2 for flats side in a CD-refiner. (GMS-V2A01 and
GMS-V2T01).
BRM Ind.bus type
0=no bus, 1= Profinet, 2=Profibus, 3=Ethernet IP.
BRM Serial no.
The unit serial number.
BRM HW. Rev.no.
Actual hardware revision.
BRM DCS clock
Synch value from DCS/PLC over the industrial bus. 0 means no contact, 1-255 is a
value that increases continuously.
BRM Test func.
Test function (not used).
BRM Date
Date and time.
5.2 CAN-Eth.-Conv.
The function is only valid and shown in a BRM-DM2.
CEC Off/ON/On-Al
Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function.
CEC IP Address
IP-address
CEC IP Mask
IP-mask.
5.3 Rotor position
POM Off/On/On+Al
Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function.
POM Direction
Direction, set to 0 or 1 depending of the type and thread of the control rod.
POM Ratio
Ratio, set 1.00 for a flat refiner and like 0.20 for a conical.
POM Al.Lim. 1HH
Alarm limit 1, high-high.
POM Al.Lim. 2H
Alarm limit 2, high.
POM Al.Lim. 3L
Alarm limit 1, low.
POM Zero calibr.
Zero calibration, see the calibration manual for actual measure system.
POM Span calibr.
Span calibration, see the calibration manual for actual measure system.
POM Work mode
Shows alternately distance, and speed for the latest rotor travel.
5.4 Ref. vibration
VIM Off/On/On+Al
Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function.
VIM Al.Lim. 1HH
Alarm limit 1, high-high.
VIM Al.Lim. 2H
Alarm limit 2, high.
5.5 Touch vibration
TVD Off/On/On+Al
Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function.
TVD Sens. Idle
Sensitivity at idle.
TVD Sens. Prod.
Sensitivity at production.
TVD Al.lim.1 Hg2
Alarm limit 1, idle, high-high.
TVD Al.lim.2 Hg1
Alarm limit 2, idle, high.
TVD Al.lim.3 Lg2
Alarm limit 3, production, high-high.
TVD Al.lim.4 Lg1
Alarm limit 4, production, high.
TVD Pro.adj.sen.
Adjusted sensitivity at production. The value can also be controlled from an external
source, like an industrial bus.