2A.1.  Hold Barrier firmly 

in position, 

pressing 

down at Lifting Point 

2A.2  Position the Direction Switch 

outwards on Ratchet Handle 
(towards user)

2A.4   Barrier is secure when 

resistance is felt on the 
Ratchet Handle, 

check 

that no movement of 
the Barrier is possible
 
within the reveals. Return 
the Ratchet Handle to the 
verticle position

STEP 2A: EXTENDING THE SIDE PANELS – SINGLE BARRIER

SECTION C: Installing the barrier(s)

The barrier must be secure at this point, to create watertight seal

2A.5   ‘Max’ extension is

 

marked 

at the top of each side 
panel. If the barrier is not 
secure at this point, see 
Section H Troubleshooting

2A.3  Jack the Ratchet Handle 

to extend the Side Panels, 
continue until the Barrier is 
secure within reveals

2

1

3

4

0

780mm –1100mm

bar

2

1

3

4

0

bar

780mm –1100mm

2

1

3

4

0

780mm –1100mm

bar

2

1

3

4

0

bar

780mm –1100mm

2A.6   Check that the 

door closes without 
interference.
If there is interference, 
see Section H 
Troubleshooting

8

CAUTION: WEAR GLOVES TO PREVENT INJURY AT PINCH POINTS 

SECTION C: Installing the barrier(s)

STEP 1B: POSITION EXTENSION POLE AND MULTIPLE BARRIERS

1B.2   Remove the lid of the base socket and insert all 

extension pole(s) into the fixed base(s). Ensure 
extension pole is at right angles to the ground. 
Slot into ground and twist/screw into position 
to create a watertight seal

1B.1   Clear any dirt or debris from the doorstep and 

reveals. For an enhanced seal, double over 
filler to create a thick strip and place at each 
corner of the doorstep/reveals, in line with 
the barrier position. Filler is not needed at 
the extension pole (due to the inbuilt  
chamfer seals)

1B.2   Wearing gloves, remove the barriers one at a 

time from the reusable packaging. Hold the 
Barrier firmly in place at the Lifting handles 
until securely positioned

1B.3   Position the barriers vertically, between the 

reveal and extension pole or between 2 
extension poles as relevant (Ratchet Handle 
facing inwards). 

CONTINUE TO STEP 3, 
INFLATE THE SEAL

Help from another person may be needed to lift safely, 
lift only at the Lifting Handles marked

9

2

1

3

4

0

780mm –1100mm

bar

2

1

3

4

0

bar

780mm –1100mm

780mm –1100mm

1100mm –3300mm

30.7in – 43.3in

780mm –1100mm

30.7in – 43.3in

780mm –1100mm

30.7in – 43.3in

43.3in – 129.9in

1100mm –3300mm

43.3in – 129.9in

1100mm –3300mm

43.3in – 129.9in

1100mm –3300mm

43.3in – 129.9in

780mm –1100mm

30.7in – 43.3in

780mm –1100mm

1100mm –3300mm

30.7in – 43.3in

780mm –1100mm

30.7in – 43.3in

780mm –1100mm

30.7in – 43.3in

43.3in – 129.9in

1100mm –3300mm

43.3in – 129.9in

1100mm –3300mm

43.3in – 129.9in

1100mm –3300mm

43.3in – 129.9in

780mm –1100mm

30.7in – 43.3in

ONLY LIFT FROM HERE WHEN MOVING

PRESS DOWN HERE WHEN INSTALLING

NEVER LIFT USING PUMP HANDLE

CAUTION

2.0

1.0

3.0

4.0

0

A

B

The 

Dam Easy

®

Extension Pole allows the use of multiple Dam Easy

®

 

Flood Barriers covering openings 

beyond 1.7m/67in wide. The installation 

Dam Easy

®

Extension Pole is undertaken in 2 stage

s:

BASE SOCKET INSTALLATION – A one-off installation to secure the base socket into the ground (concrete). 
Please note Base Socket installation will need to be carried out prior to proceeding with installation of 
multiple barriers.

POLE INSTALLATION – A quick and simple instalation to fix the Extension Pole into the base socket.

2

1

3

4

0

780mm –1100mm

bar

2

1

3

4

0

bar

780mm –1100mm

NOTE: You must push down 

firmly on the barrier to ensure 

it is tight to the ground.

90

0

Содержание DME01

Страница 1: ...Instruction Manual Certificate no EVH022 AWI O2 04 16 Valid until 04 2019 NO TOOLS NO FIXINGS NO SILICONE NO DRILLING ...

Страница 2: ...e solution on the market All Weather Industries designed the Dam Easy Flood Barrier The Dam Easy Flood Barrier provides temporary flood protection for doorways How it works Within suitable doorways the Dam Easy Flood Barrier extends to fit securely within reveals 780mm 1100mm 30 7in 43 3in wide Inflation of unique patented inflatable seal creates a watertight seal in seconds The Dam Easy Flood Bar...

Страница 3: ... Doorway To achieve a watertight seal and allow clearance to close the door reveals must be smooth solid verticle and parallel minimum size Width 780 1100mm 30 7in 43 3in single barrier Width 1100mm 43 3in multiple barriers Height 720mm 28 3in Depth 75mm 3in single barrier installation Depth 120mm 4 7in multiple barrier installation Doorstep must be smooth solid and horizontal at right angles to r...

Страница 4: ...use as detailed in this instruction manual retain for future use available to download www dameasyfloodbarriers com The barrier weighs 19 7kg 43 4lb take care when lifting 2 people may be needed to lift the barrier safely Complete a full trial installation of the barrier in the doorway that requires flood protection prior to a risk of flooding Flood water may be contaminated always use gloves and ...

Страница 5: ... the doorstep reveals in line with the barrier position Filler is not needed at the extension pole due to the inbuilt chamfer seals 1B 2 Wearing gloves remove the barriers one at a time from the reusable packaging Hold the Barrier firmly in place at the Lifting handles until securely positioned 1B 3 Position the barriers vertically between the reveal and extension pole or between 2 extension poles...

Страница 6: ...n pressure A drop in pressure may indicate a problem see Section H Troubleshooting 3 2 Inflate the Seal using the Pump Handle 2 1 3 4 0 780mm 1100mm bar 3 6 Repeat for each barrier for multiple barrier installations Installation of the Barrier s is now complete and ready to protect the doorway from flood water TOP TIP To prevent accidental deflation of the seal or unauthorised removal of the barri...

Страница 7: ...STEP 2 CAUTION WEAR GLOVES AND HOLD THE BARRIER S SECURELY AT THE Lifting handles TO AVOID INJURY AS THE SIDE PANELS RETRACT AND BARRIER IS NOT SECURED IN PLACE 2 3 For multiple barrier installations retract barrier 1 2 etc gradually in series to avoid excess pressure on the extension pole s 3 1 If the barrier s has not been in contact with flood water hold securely at the lifting point and retrac...

Страница 8: ...t seal from the packaging before use Do not use any tools while replacing the seal SECTION F Replacing the seal WHEN TO REPLACE THE SEAL 14 TOP TIP Avoid damaging the seal by always placing the barrier on a smooth even surface when not installed in a doorway and store in the original packaging CAUTION IMPORTANT SECTION E Cleaning the barrier 2 1 3 4 0 780mm 1100mm bar 2 1 3 4 0 bar Floodwater may ...

Страница 9: ... 2 0 1 0 3 0 4 0 0 STEP 2 FITTING REPLACEMENT SEAL Do not remove the replacement seal from packaging until immediately before replacement Place the barrier flat on a smooth even surface to safely replace the seal 1 Insert the Seal Valve at the centre of the seal into the opening on the underside of the barrier and carefully secure to the inflation mechanism by compressing the Quick Release Fitting...

Страница 10: ...are not suitable for a Dam Easy flood barrier protection 2 Reposition the barrier within the reveals further from the door and repeat barrier installation 3 Reposition the barrier within the reveals further from the door or remove the door furniture and repeat barrier installation Barrier rises when seal is inflated The barrier is not sufficiently secured in the doorway Deflate the seal and repeat...

Страница 11: ... Baths from flood ingress through the waste pipes Toilet Dam Prevents water rising through toilets during flooding Suitable for most makes and models The Dam Easy Toilet Dam is an effective tool for blocking any width or shape of toilet pan against sewage backflow during a flood HydroSnake Sandless bag solution for temporary protection against low level flooding The HydroSnake is a highly effectiv...

Страница 12: ...ries Limited its directors employees shareholders agents or subcontractors be liable to you for indirect incidental consequential special or exemplary damages All Weather Industries Limited accepts no responsibility for any loss or damage caused by All Weather Industries Limited or all All Weather Industries Limited s employees agents or subcontractors where such loss is a not a forseeable result ...

Страница 13: ...rther information or demonstrations please visit www dameasyfloodbarriers com All Weather Industries Unit 19A Ardee Business Park Hale Street Ardee Co Louth Ireland NO TOOLS NO FIXINGS NO SILICONE NO DRILLING ...

Отзывы: