Standard Driver Mode
In standard mode, the Spyder3 GEV operates with any vendor’s Ethernet network
adapter. The driver shipped with the adapter transfers the data to the Windows network
stack, which handles IP communications tasks.
Efficiency
★ ☆ ☆ ☆ ☆
Usage
Low-bandwidth application or temporary
Standard mode is recommended for applications where flexibility is more important than
performance. The Windows network stack uses significant levels of CPU processing
power to transfer data to memory, which can result in lost packets, severely degrading
performance.
Standard mode is thus suitable for applications that require bandwidths of only 100 Mb/s
or less. If this mode is used with bandwidths of 1 Gb/s, application performance will
greatly degrade when CPU usage hits 100%. Additionally, at high rates like these,
insufficient CPU resources may be available to process or even display images.