Spyder3 SC-34 Color Camera User's Manual
29
Teledyne DALSA
03-032-20116-01
Mode 8: Maximum Line Rate, Programmable Exposure Time
In this m od e, the exp osu re tim e is set internally w ith a m axim u m line rate.
Figure 15: Mode 8 Timing
Setting the Line Rate
Pu rp ose:
Sets the camera‘s line rate in Hz. Camera must be operating in
exp osu re m od e 2 or 7.
Syntax:
ssf
f
Syntax Elem ents:
i
Desired line rate in H z. Allow able valu es are:
2k 2 tap :
300 - 18000
H z
4k 2 tap :
300- 9000
H z
N otes:
To read the cu rrent line frequ ency, u se the com m and
gcp
or get
ssf.
If you enter an invalid line rate frequ ency, an error m essage is
retu rned .
Related Com m and s:
sem, set
Exam p le:
ssf 10000
Setting the Exposure Time
Pu rp ose:
Sets the camera‘s exposure time is µs. Camera must be operating in
exp osu re m od e 2, 6, or 8.
Syntax:
set
f
Syntax Elem ents:
i
Desired exp osu re tim e in µs. Allow able range is
3
to
3300
µs.*
N otes:
To read the cu rrent line frequ ency, u se the com m and
gcp
or get
set.
If you enter an invalid line rate frequ ency, an error m essage is
retu rned .
*The exp osu re tim e range is based on the cu rrent line rate.
To d eterm ine the m axim u m exp osu re tim e allow ed for the
cu rrent line rate, u se the com m and get ger.
Related Com m and s:
sem, ssf
Exam p le:
set 400.5
Pu rp ose:
Sets the selected p in to u se either TTL or LVDS stand ard s.
Programmable Period
Frame Period
Readout
CR Exposure Time
CR=Charge Reset
Frame Period
Programmable Period
CR Exposure Time
Readout
i
Applies to Modes 2 and
7
i
Applies to Modes 2 and
8