Spyder3 Color Manual
75
DALSA
03-032-20059-01
SRM 0, Auto Mode.
Time Period
Operating Region
Operating Mode
T
0
Immediate Readout state
T
1
Dark Current Dump state
T
2
Immediate Readout state
SRM 2, Immediate Readout Mode.
Time Period
Operating Region
Operating Mode
T
0
Dark Current Dump state
T
1
Immediate Readout state
Dark Current Dump to Immediate Readout (T
INT
< #)
Valid
T
VERT_TRANS
LVAL
EXSYNC
T
DUMP
T
INT
F
DUMP
> DUMP (MAX)
F
Dark Current Dump to Immediate Readout (T
INT
> #)
Valid
EXSYNC
T
DUMP
T
INT
T
VERT_TRANS
LVAL
F
DUMP
> DUMP (MAX)
F
Immediate Readout to Dark Current Dump: Hysteresis Artifacts
SRM 0, Auto Mode.
Time Period
Operating Region
Operating Mode
T
0
Immediate Readout state